Installation Instructions; Structure Of Unit; Technical Data; Provisions And Specifications - AEG WKL 503 Operating And Installation Instructions

Wall-mounted electric direct heater
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
2.

Installation instructions

This unit may only be erected and electrically connected by a specialist following the installation
instructions.
First remove the packaging and check accessories and any enclosures, ensure that no accessories remain
in the packaging material.
2.1

Structure of unit

4 Air outlet grid
5 Wall bracket
6 Closing bolt
7 Mains connection cable
8 Rating plate

Technical data

Type
Height
Width
Depth
with wall bracket
Dimension A
Weight
Connection
Power
Temperature
adjustment range
Frost protection
Protection class
Protection mode
Approval
2.2
Provisions and specification
The unit should not be operated
– in rooms at risk of explosion or fire from chemicals, dust, gas or vapour,
– in the immediate vicinity of pipes or containers which transport or contain flammable or
explosive substances,
– if the minimum distances from adjacent object surfaces are not observed.
In workshops or other rooms in which exhaust gases, oil or petrol vapours etc. occur or where solvents
and chemicals are used, persistent odour problems and where applicable contamination can occur.
The unit may only be fitted to a vertical wall, temperature-resistant up to at least 80 °C.
Minimum distances from adjacent object surfaces must be observed.
All electrical connection and installation work must be performed to VDE regulations (0100), the regula-
tions of a competent utility company and the corresponding national and regional regulations.
The unit must not be mounted directly below a wall socket.
If the unit is permanently connected to an AC network (junction box) an isolation distance of
at least 3mm is required on all poles for isolation from the network. For this, circuit breakers,
LS switches, fuses etc. can be used.
Installation with permanent connection cables is not permitted.
The rating plate must be observed. The rated voltage must correspond to the nominal voltage.
14
WKL 503 S
WKL 753 S
WKL 503 U
WKL 753 U
mm
mm
370
445
mm
mm
11
195
kg
4,0
4,6
kW
0,5
0,75
ºC
ºC
WKL 1003 S
WKL 1503 S
WKL 2003 S
WKL 1003 U
WKL 1503 U
WKL 2003 U
450
445
590
78
100
195
343
4,6
6,0
1/N ~ 30 V
1,0
1,5
approx. 6 to 30
approx. 6
II
IP 4, splash water protected
see unit rating palte
for the professional installer
WKL 2503 S
WKL 3003 S
WKL 2503 U
WKL 3003 U
740
890
491
639
7,2
8,4
,0
,5
1040
787
9,9
3,0