This appliance complies with: European Council
Directives Low voltage Directive 73/23/EEC,

Installation

MODEL NAME
ZCG561FW
ZCG562FW
ZCG562FM
1) For more information, refer to Technical Data.
Safety requirements
• Natural Gas / LPG versions of this appliance are
available.
• Check that this model is suitable for the type of
supply available. This appliance must be installed
and/or serviced by a competent person in
accordance with the Gas Safety (Installation and
Use) Regulations Current Editions and the I.E.E.
Wiring Regulations.
• Detailed recommendations are contained in the
following British Standard Codes of Practice -
BS.6172, BS.5440: Part 2 and B.S. 6891. All British
Standards must be 'Current Editions'.
• For appliances installed in the Republic of Ireland
please refer to NSAI – Domestic Gas Installation
IS813 Current Editions and the ETCI Rules for
Electrical Installations. In the Republic of Ireland a
signed Declaration of Conformity is issued by the
installer (Is813 Current Editions Annex D.1).
!
WARNING!
This appliance must be installed by a qualified
electrician / competent person (Gas safe registered).
Safety may be impaired if installation is not carried
out in accordance with these instructions. Do not alter
the electrical circuitry of this appliance.
Provision for ventilation
• This appliance is not connected to a combustion
products evacuation device. It should be installed
and connected in accordance with the current
installation regulations. Particular attention should
be given to the relevant requirements regarding
ventilation.
• The room containing the appliance should have an
Gas Directive 90/396/EEC EMC Directive
89/336/EEC, CE Marking Directive 93/68/EEC.
MODEL RECOGNITION TABLE
COLOR
WHITE
WHITE
BROWN
air supply in accordance with BS. 5440: Part 2
Current Edition. All rooms require an openable
window or equivalent and some rooms will require
a permanent vent as well. For room volumes up to
5m³ an air vent of 100cm² is required: for room
volumes between 5m³ and 10m³ an air vent of
50cm² is required. If the room has a door that
opens directly to the outside, no air vent is
required. For room volumes that exceed 11m³ no
air vent is required. If there are other fuel burning
appliances in the same room, BS.5440: Part 2
Current Edition should be consulted to determine
the requisite air vent requirements.
• Prolonged intensive use of the appliance may call
for additional ventilation, for example opening a
window, or more effective ventilation, for example
increasing the level of mechanical ventilation where
present.
Moving your appliance
• You may damage some soft or badly fitted floor
coverings when you move the appliance. The floor
covering under the appliance should be securely
fixed so it does not ruck up when you move the
appliance across it. Alternatively you could remove
the floor covering. This appliance is heavy and care
must be taken when moving it. Do not try to move
the appliance by pulling the door handles.
• To move the appliance, open the grill door. Raise
the appliance off its front feet by lifting it from inside
the oven. Pull the appliance forward. When you
replace the appliance push it back to the stop and
make sure there is the same gap at each rear
corner.
1)
GAS TYPE
NG
LPG
LPG
17