Download Print this page

Auto, Heat, Cool, Dry; Operation Details - Panasonic CU-W12EKR Operating Instructions Manual

Panasonic air conditioner user manual
Hide thumbs

Advertisement

AUTO, HEAT, COOL, DRY

2
2
Select the
desired
operation.
● Supersonic air purifying device (super alleru-buster) operates
automatically once the unit is switched on.
QUIET
POWERFUL
and
operations are available in all modes.
OFF/ON
● Press
again to stop the operation.
Troubleshooting
● Mist emerges from indoor unit.
● Heating/Cooling operation does not work.
● Water fl owing sound during operations.
● The power indicator blinks during the operation and
the indoor fan is stopped.
FAN
AUTO
SPEED
HEAT
AIR
COOL
SWING
DRY
OFF
OFF
ON
TIMER
TIMER
OFF/ON
MODE
QUIET
FAN SPEED
TEMP
POWERFUL
AIR SWING
TIMER
ON
SET
1
2
3
OFF
CANCEL
SET
RESET
CLOCK
1
1
Start the
operation.
3
3
Set the
temperature.
► Condensation effect due to cooling process.
► Ensure temperature is set correctly.
► Make sure windows and doors are closed.
► Make sure fi lters are cleaned and replaced.
► Make sure inlet and outlet vents are cleared.
► Cause by refrigerant fl ow inside the unit.
► The unit is in defrost mode, and the melted frost is drained from the
outdoor unit.

Operation Details

AUTO - Automatic Operation
• Unit selects the operation mode
according to the room temperature.
• Once the operation mode is
selected, the unit will operate at
the standard setting temperature
as shown:
Standard
Room
Operation
setting
temperature
mode
temperature
23°C &
Cool
25°C
above
Below
Dry
22°C
23°C
Below
Heat
21°C
20°C
• Press
or
to change the
temperature setting to "HI" or "LO"
as shown:
Operation mode
HI
LO
Cool
27°C
23°C
Dry
24°C
20°C
Heat
23°C
19°C
HEAT - Heating Operation
• In heating mode, it takes a while
for the unit to warm up. The
power indicator blinks during this
operation.
• The range of temperature can be
selected from 16°C ~ 30°C.
COOL - Cooling Operation
• Enjoy cool air at your desired
temperature.
• The range of temperature can be
selected from 16°C ~ 30°C.
DRY - Soft Dry Operation
• Keep your environment
dehumidifi ed by running cooling
operation at a low fan speed.
• The range of temperature can be
selected from 16°C ~ 30°C.
Hint
• A temperature setting 1°C higher
in cooling operation or 2°C lower in
heating operation than the desired
temperature equates to a 10%
power saving.