TO SELECT FAN SPEED
(5 OPTIONS)
• For AUTO, the indoor fan speed is automatically
adjusted according to the operation mode.
TO ADJUST AIRFLOW DIRECTION
AIR SWING
(5 OPTIONS)
• Keeps the room ventilated.
• In COOL/DRY mode, if AUTO is set, the louver swing
left/right and up/down automatically.
• In HEAT mode, if AUTO is set, the horizontal louver fi x
at predetermined position. The vertical louver swing
left/right after the temperature rises.
TO MONITOR AIR
QUALITY
• Patrol sensor detects air quality.
• When air quality is unsatisfactory, e-ion operation will
start automatically.
TO SAVE ELECTRICAL
ECONOMY
POWER CONSUMPTION
• Save power consumption at unoccupied room by
adjust set temperature up to 3°C automatically.
• Brightness of all indicators will be dimmed.
QUIET
POWERFUL
QUIET/ POWERFUL
TO ENJOY QUIET ENVIRONMENT
• This operation reduces indoor and
outdoor units noise.
TO ACHIEVE TEMPERATURE QUICKLY
• This operation will stop automatically
after 20 minutes.
TO IMPROVE HUMIDITY
MILD DRY
AND MOISTURE LEVEL
• This operation reduces air dryness and provides you
with a comfortable living environment.
• When vertical airflow direction is set to AUTO, it
stops at lower position to avoid cold air contact.
However, you can adjust the louver direction
manually.
QUIET/ POWERFUL
ECONOMY
,
and
all modes and can be cancelled by pressing the
respective button again.
only can be activated in COOL mode and can
MILD DRY
be cancelled by pressing the button again.
QUIET/ POWERFUL
,
and
MILD DRY
ECONOMY
the same time.
can be activated even when the unit is turned
off. In this condition, once e-ion operation is ON, the
unit will operate with AUTO fan speed and air swing.
ECONOMY
NORMAL
QUIET
POWERFUL
MILD DRY COOLING
can be activated in
cannot be activated at
TO SET THE TIMER
TO SET THE TIMER
• 2 sets of ON and OFF timers are available to turn ON or
OFF the unit at different preset time.
Select ON or OFF Timer
1
1
2
2
Cancel
Cancel
1
1
2
2
Cancel
Cancel
• Example of application at living room:
Morning: ON 1 at 07:00 (Wake up)
OFF 1 at 08:00 (Out for work)
Evening: ON 2 at 17:00 (Back home)
OFF 2 at 22:00 (Sleep)
• To cancel ON or OFF timer, press
select respective 1 or 2 then press
• If timer is cancelled manually or due to power failure,
you can restore the timer again by pressing
to select respective 1 or 2 then press
• Upcoming timer will be displayed and will be activated
in sequence.
• When ON Timer is set, the unit may start earlier (up
to 35 minutes) before the actual set time in order to
achieve the desired temperature on time.
• Timer operation is based on the clock set in the remote
control and repeats daily once set. For clock setting,
please refer to Remote Control Preparation at back
cover.
OPTIONAL SETTINGS
OPTIONAL SETTINGS
Patrol starts automatically with the unit
switched on with
Press and hold for 5 seconds, then release
to disable or restore this setting.
Press and hold for 5 seconds to dim or
restore the unit's indicator brightness.
Press and hold for approximately 10
seconds to show temperature setting in
°C or °F.
Press to restore the remote control's default
setting.
Not used in normal operations.
,
Use curtains to screen off sunlight and outdoor heat to
reduce power consumption during cool mode.
Set the
Confi rm.
time.
TIMER
or
to
.
or
.
.
5