Panasonic CS-E12GFEW-2 Service Manual page 5

Panasonic air conditioner user manual
Hide thumbs Also See for CS-E12GFEW-2:
Table of Contents

Advertisement

ITEM
Type
Material
Motor Type
Input Power
Output Power
Fan
Fan Speed
Fin Material
Fin Type
Heat Exchanger
Row x Stage x FPI
Size (W x H x L)
Material
Air Filter
Type
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry
Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb)
Item
Power Source (Phase, Voltage, Cycle)
Input Power
Starting Current
Running Current
Maximum current
Power Factor
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Number of core
Power Cord
Length
Thermostat
Protection Device
Note
• Specifications are subject to change without notice for further improvement.
UNIT
W
W
QLo (Cool/Heat)
rpm
Lo (Cool/Heat)
rpm
Me (Cool/Heat)
rpm
Hi (Cool/Heat)
rpm
SHi (Cool/Heat)
rpm
mm
Unit
ø
V
Hz
W
A
A
A
%
m
5
INDOOR UNIT
Turbo Fan
ASG
Transistor (8-pole)
48
360 / 360
410 / 410
510 / 520
620 / 630
660 / 670
Aluminium (Pre Coat)
Slit Fin
2 x 22 x 19
510 x 396 x 24
PET
Honeycomb
Single
220 - 240
50
Cooling; 570 (175 ~ 780)
Heating; 865 (165 ~ 1360)
4.20
Cooling; 2.75 - 2.65
Heating; 4.20 - 3.90
6.15
Cooling; 94 - 90
Heating; 94 - 92
Electronic Control
Electronic Control
OUTDOOR UNIT
Propeller Fan
PP
Induction (6-pole)
66.0 - 74.1
25
745 - 790 / -
Aluminium (Pre Coat)
Corrugated Fin
2 x 24 x 17
36.4 x 504 x 713
684

Advertisement

Table of Contents
loading

Table of Contents