Stirling STR-SSAC12000 Installation Manual
Stirling STR-SSAC12000 Installation Manual

Stirling STR-SSAC12000 Installation Manual

Reverse cycle inverter split system air conditione
Hide thumbs Also See for STR-SSAC12000:

Advertisement

PROTECT YOUR WARRANTY
This unit must be installed by a registered,
licensed installer as required by
Government regulations.
Reverse Cycle Inverter
Split System Air Conditioner
Model Number STR-SSAC12000
INSTALLATION MANUAL
IM Version No: V1.1
Issue Date: 01 October 2015
AFTER SALES SUPPORT
info@tempo.org
AUS
1300 886 649
MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the STR-SSAC12000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Stirling STR-SSAC12000

  • Page 1 Government regulations. Reverse Cycle Inverter Split System Air Conditioner Model Number STR-SSAC12000 INSTALLATION MANUAL IM Version No: V1.1 Issue Date: 01 October 2015 AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 2: Welcome

    We hope you will enjoy using your purchase for many years to come. AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 3: Table Of Contents

    Contents Welcome Warranty Details General Safety Instructions Product Overview Selecting the Installation Place Installation Technical Specifications Other Useful Information Repair and Refurbished Goods or Parts Notice AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 4: Warranty Details

    You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 5: General Safety Instructions

    • Make sure that after installation the power plug can easily be reached. AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 6 Therefore only trained technicians with an appropriate refrigerant certificate may service the appliance for filling or emptying. AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 7: Product Overview

    The indoor unit must be wall-mounted in the room to be air conditioned; the outdoor unit can be installed outdoors on the ground, or on an outside wall on suitable brackets. AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 8: Selecting The Installation Place

    Do NOT install the indoor unit: 2 Near a source of heat, steam or flammable gas 2 Near a doorway 2 Where it will be exposed to direct sunlight. Fig. 3 AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 9: Outdoor Unit

    Required Amount of Additional Max. Allowable Limit of Limit of R-410A Refrigerant (g/m) Distance Tubing Elevation between Units Length Difference H Cooling Capacity: ≤12000BTU AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 10: Installation

    • Note: To block up the connector, use a tool like a screwdriver to Fig. 8 plug the rubber stopper into the connector, as pictured in Fig.8. AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 11 • To check the water discharge, put a cup of water into the groove and check whether the water flows through the water discharge hole. AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 12: Installing The Outdoor Unit

    Otherwise, measures such as reinforcement, support or vibration damping should be adopted. Fig. 11 Outdoor Unit Size (mm) A (mm) B (mm) 802 x 298 x 535 AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 13: Pipe Connection

    Fig.12 above, until it is tightly fastened. • Pointing towards the centre of the pipe, fasten the screw firmly (Fig.13). Wrench the nut until it clicks securely into place. Fig. 13 AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 14 (Fig.15). • Use clips or other fixtures to fasten the pipes to the walls. AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 15 IMPORTANT: Check all piping and connections and ensure there is no leakage. Test the unit with soapy water for leakage. Fig. 16 Vapour side Stop valve (open) T-branch valve (open) AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 16 Low pressure charge hose. 8. Fully open the packed valve stems B and A. 9. Securely tighten the cap of the packed valve. AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 17: Electrical Connection

    Fig.18 below, using the pressing board to fasten the connection cables. (The STR-SSAC12000 is a variable speed unit.) Open the front panel, if the indoor unit is fitted with the signal wire, detach the mid-frame and insert the signal wire through the bottom frame, then connect the signal wire quick plug of the indoor to the outdoor unit.
  • Page 18: Important Notes

    (Fig.20). Wrong connection may cause electric shock or fire. Fig. 20 Wiring Diagram for Variable Speed Units Indoor Unit Outdoor Unit AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 19: Test Run

    • Test the temperature going into and coming out of the air conditioner. Make sure that the air conditioner can achieve a temperature difference between the outside air and the air at the indoor outlet of at least 10°C. AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 20: Technical Specifications

    Fan speed (rpm) (T/H/M/L) Outdoor Liquid Connections Connecting pipe (inch) Condensate drainage pipe (mm) (OD*L) 16.9*2000 Indoor 970*235*315 Dimensions (mm) Other Outdoor 802*298*535 specifications Indoor Weight (kg) Outdoor AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 21: Other Useful Information

    Do not attempt to repair the unit yourself! Spare Parts Our after sales support centre stocks the following spare parts for the STR-SSAC12000 Reverse Cycle Inverter Split System Air Conditioner. To purchase a part, call the centre on 1300 886 649 or email us at info@tempo.org •...
  • Page 22 Contact your local authorities for advice on recycling facilities in your area. AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 23: Repair And Refurbished Goods Or Parts Notice

    Telephone: 1300 886 649 (Aust) - Fax: (02) 9975 2688 Tempo Help Desk: 1300 886 649 (Aust) (Operating Hours: Mon-Fri 08:30am to 06:00pm EST) Email: info@tempo.org AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...
  • Page 24 For an electronic copy of this manual, go to www.stirlingappliances.com.au and download a copy. Instruction Manual Revision Index Version No Issue Date Description V1.0 23 September 2015 Original release V1.1 01 October 2015 Compliance updates AFTER SALES SUPPORT info@tempo.org 1300 886 649 MODEL: STR-SSAC12000 PRODUCT CODE : 51673 12/2015...