WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
REMOVING THE OVEN LIGHT ASSEMBLY
(ONE ON EACH SIDE OF OVEN)
Remove the electrical quick disconnect plug from
the back.
From the inside of the oven cavity unsnap the light
lens and light bulb and snap the light assemble
out and pull (fish) the wire harness from the
back.
REMOVING THE CONVECTION FAN
MOTOR
From the back of the oven disconnect the two
electrical connections to the fan motor.
From the inside of the oven, remove the
convection cover at the back of the oven cavity.
Remove the fan blade from the convection
motor shaft.