Rheem CRITERION II PLUS 2 LXE RGPL- SERIES Manual

Rheem CRITERION II PLUS 2 LXE RGPL- SERIES Manual

Two stage a.f.u.e. upflow/horizontal gas furnaces

Advertisement

GAS FURNACES
RGPL- SERIES
ECM Equipped
Models with Input Rates from
50,000 to 125,000 BTU/HR
[15 to 37 kW]
(U.S. & Canadian Models)
ISO 9001:2000
ENER
UIDE
AFUE
Annual Fuel Utilization Efficiency -
THIS MODEL
80.0%
MID
HIGH
78%
82%
88%
97%
®
CRITERION
II PLUS 2 LXE
TWO STAGE 80% A.F.U.E.
UPFLOW/HORIZONTAL
GAS FURNACES
The Rheem
®
Criterion II Plus 2 LXE line of upflow/horizontal
gas furnaces are designed for utility rooms, closets,
alcoves, or attics. Because of the Criterion's low-profile
34 inch [864 mm] height, the upflow model installed
vertically can also be used to satisfy most applications
that traditionally call for a horizontal furnace.
The design is certified by CSA International.
Features
Patented Heat Exchanger, constructed of both stainless and
s
aluminized steel for the maximum in corrosion resistance.
Low profile "34 inch" [864 mm] design is lighter and easier
s
to handle, and leaves room for optional equipment.
Energy efficient and quiet ECM 2+ motor.
s
Improves cooling efficiency when matched with rated con-
s
densing unit and coil.
Constant CFM.
s
Dip switch settings for selectable heating temperature rise
s
and cooling airflow.
On-demand dehumidification terminal for improved com-
s
fort in cooling mode.
Convertible from upflow to horizontal left or right without
s
field conversion.
Left or right side gas and electric inlet connections.
s
All models equipped with remote sense feature, an inte-
s
grated board with humidifier and electronic air cleaner
hookups.
Insulated blower compartment, a slow-open gas valve, a
s
specially designed draft inducer motor and blower motor
make it one of the quietest furnaces on the market today.
Pre-paint galvanized steel cabinet.
s
Molded permanent filter.
s
Grab-holes in doors to aid in easy door removal and
s
replacement.
Compatible with single or two-stage thermostat. (For opti-
s
mal performance, two-stage thermostat recommended.)
A variety of cooling coils and plenums designed to use with
Rheem Criterion II Plus 2 LXE gas furnaces are available as
optional accessories.
✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of
Energy test procedures.
FORM NO. G11-473 REV. 5
Supersedes Form No. G11-473 Rev. 4

Advertisement

Table of Contents
loading

Summary of Contents for Rheem CRITERION II PLUS 2 LXE RGPL- SERIES

  • Page 1 Compatible with single or two-stage thermostat. (For opti- mal performance, two-stage thermostat recommended.) A variety of cooling coils and plenums designed to use with Rheem Criterion II Plus 2 LXE gas furnaces are available as ISO 9001:2000 optional accessories. ✝A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of...
  • Page 2: Standard Equipment

    Completely assembled and wired; 2 speed draft inducer; high and low pressure All models can be converted by a qualified Rheem distributor or local service switches; redundant 2 stage main gas control; blower compartment door safety dealer to use L.P.
  • Page 3 ➁ See Conversion Kit Index Form for high altitude derate. GENERAL TERMS OF LIMITED WARRANTY Rheem will furnish a replacement for any part of this product Gas Heat Exchanger Limited Warranty ..Twenty (20) Years which fails in normal use and service within the applicable *Any Other Part..........Five (5) Years...
  • Page 4: Upflow Dimensions

    ➂ May be 1" [25 mm] with type B vent. Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes. [ ] Designates Metric Conversions Rheem Manufacturing Company...
  • Page 5: Horizontal Dimensions

    ➂ May be 1" [25 mm] with type B vent. Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes. [ ] Designates Metric Conversions Rheem Manufacturing Company...
  • Page 6: Accessories

    RXPF-F01 and F02 HIGH ALTITUDE KIT—Required for all models at altitudes of 5,000 FOSSIL FUEL KIT—is for use with Rheem Heat Pumps and ft. and above. Use kit # RXGY-F13 for all -GPL models. Criterion II Plus 2 LXE warm air furnaces. RXPF-F02 meets OPTION CODE FOR HIGH ALTITUDE: TVA requirements.
  • Page 7 [746] 1400 [661] 1200 [566] HIGH 2000 [944] 11 x 10 MED-HI 1600 [755] [279 x 254] [746] 1400 [661] 1200 [566] Note: See Form Number C11-206 for MultiFlex ® coil data. [ ] Designates Metric Conversions Rheem Manufacturing Company...
  • Page 8 Federal, State, Provincial, and Local codes, regulations, and practices. 5600 Old Greenwood Road, Fort Smith, Arkansas 72908 “In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.” PRINTED IN U.S.A. 8-05 DC FORM NO.

Table of Contents