  • Page 1 Absorber refrigerator Installation Manual....15 RM5310, RM5330, RM5380, RM5385...
  • Page 3 RM5310 – RM5385 486 mm 474 mm RM 5310 486 mm 474 mm RM 5330 118 mm 486 mm 474 mm RM 5380 486 mm 474 mm RM 5385...
  • Page 4 RM5310 – RM5385 RM 5310 RM 5330 RM 5380 RM 5385...
  • Page 5 RM5310 – RM5385...
  • Page 6 RM5310 – RM5385 min. 15 mm...
  • Page 7 RM5310 – RM5385...
  • Page 8 RM5310 – RM5385...
  • Page 9 RM5310 – RM5385...
  • Page 10 RM5310 – RM5385 SW 17 SW 14...
  • Page 11 RM5310 – RM5385 – ge/gn Blue Brown Yellow Green Black...
  • Page 12 RM5310 – RM5385 – – – ge/gn Blue Brown Yellow Green Black White...
  • Page 13 RM5310 – RM5385 HE OUT 12 VDC HE IN (+) (-) B C D E Brown Black White...
  • Page 14 RM5310 – RM5385 RM 5310 RM 5330 RM 5380 RM 5385...
  • Page 15: Table Of Contents

    RM5310 – RM5385 Please read this instruction manual carefully before installation and first use, and store it in a safe place. If you pass on the product to another person, hand over this instruction manual along with it. Table of contents Explanation of symbols .
  • Page 16: Explanation Of Symbols

    Explanation of symbols RM5310 – RM5385 Explanation of symbols WARNING! Safety instruction: Failure to observe this instruction can cause fatal or serious injury. CAUTION! Safety instruction: Failure to observe this instruction can lead to injury. NOTICE! Failure to observe this instruction can cause material damage and impair the function of the product.
  • Page 17 RM5310 – RM5385 Safety instructions  If the AC power cable for this refrigerator is damaged, it must be replaced by the manufacturer, customer service or a similarly qualified person in order to prevent safety hazards.  Never use a naked flame to check the refrigerator for leaks.
  • Page 18: Scope Of Delivery

    Scope of delivery RM5310 – RM5385  Only use the AC connection cable supplied to connect the refrigerator to the AC mains.  Only use cables with a suitable size.  Never pull the plug out of the socket by the connection cable.
  • Page 19: Intended Use

    Note the following dimensions here (H x W x D in mm, fig. 1, page 3): – RM5310: 618 x 486 x 474 – RM5330: 821 x 486 x 474 – RM5380: 821 x 486 x 474 –...
  • Page 20 Installing the refrigerator RM5310 – RM5385  If the ventilation grille of the air inlet vent cannot be installed flush to the ground, an additional inlet vent (fig. 2 5, page 4) must be provided in the floor for releasing leaked gas.
  • Page 21 RM5310 – RM5385 Installing the refrigerator The manufacturer recommends using a flexible seal to ease removal and installation for maintenance purposes. ➤ Attach the sealing lips (fig. 3 1, page 5) to a stop rail behind the refrigerator, for example, by using an adhesive.
  • Page 22 Installing the refrigerator RM5310 – RM5385 Installing the ventilation grille LS100 No. in Description fig. 5, page 5 Installation frame Ventilation grille Attachment for flue duct Winter cover LS200 No. in Description fig. 6, page 5 Installation frame Ventilation grille Winter cover Proceed as follows (fig.
  • Page 23: Securing The Refrigerator

    RM5310 – RM5385 Reversing the door ➤ Connect the flue duct and the cover plate with the T-piece (1). ➤ Shorten the flue duct (7) to the correct length if necessary. ➤ Place the LS100 ventilation grille (9) in the installation frame (6) and lock it into place.
  • Page 24: Put On The Door Panel

    The door panel must have the following dimensions:  RM5310: 534 x 455 x max. 3 – 3.8 (H x W x D in mm)  RM5330/RM5380/RM5385: 740 x 455 x max. 3 – 3.8 (H x W x D in mm) ➤...
  • Page 25 RM5310 – RM5385 Connecting the refrigerator It must be possible to shut off the refrigerator from the gas line separately by means of a shut-off device. The shut-off device must be easily accessible. ➤ Connect the refrigerator to the gas supply securely and without any voltage according to fig.
  • Page 26 Connecting the refrigerator RM5310 – RM5385 ➤ Connect the RM5310/RM5330/RM5380 refrigerators according to fig. d, page 11 (without lighting), and fig. e, page 12 (with lighting): Item Description DC heating cartridge DC connection cable Terminal strip for the DC power supply of the heating cartridge...
  • Page 27 RM5310 – RM5385 Connecting the refrigerator ➤ Connect the RM5385 refrigerator according to fig. f, page 13: Item Description AC heating cartridge AC power connection cable Earth AC power Ionisation Ignition Burner DC heating cartridge LED lighting Gas input Gas output...
  • Page 28 Connecting the refrigerator RM5310 – RM5385 ➤ Secure the power supply line to the heating element (connections 3 and 4) with a 16 A fuse and the supply for lighting/electronics (connections 5 and 6) with a 2 A fuse. ➤ Connect the heating element (connections 3 and 4) with the shortest possible cable.
  • Page 29: Cleaning And Maintenance

    RM5310 – RM5385 Cleaning and maintenance Cleaning and maintenance WARNING! Always disconnect the refrigerator from the mains before you clean and service it. NOTICE! Beware of damage  Do not allow grease or oil to come into contact with the door seal.
  • Page 30: Technical Data

    Technical data RM5310 – RM5385 Technical data RM5310 RM5330 RM5380 RM5385 Voltage: 230 Vw 12 Vg Gross capacity: 60 l 70 l 80 l 80 l Net capacity: 55 l 65 l 75 l 75 l Connection value: 125 W (230 Vw), 120 W (12 Vg) 18.3 g/h (gas)