RM5310 – RM5385 Please read this instruction manual carefully before installation and first use, and store it in a safe place. If you pass on the product to another person, hand over this instruction manual along with it. Table of contents Explanation of symbols .
Explanation of symbols RM5310 – RM5385 Explanation of symbols WARNING! Safety instruction: Failure to observe this instruction can cause fatal or serious injury. CAUTION! Safety instruction: Failure to observe this instruction can lead to injury. NOTICE! Failure to observe this instruction can cause material damage and impair the function of the product.
Page 17
RM5310 – RM5385 Safety instructions If the AC power cable for this refrigerator is damaged, it must be replaced by the manufacturer, customer service or a similarly qualified person in order to prevent safety hazards. Never use a naked flame to check the refrigerator for leaks.
Scope of delivery RM5310 – RM5385 Only use the AC connection cable supplied to connect the refrigerator to the AC mains. Only use cables with a suitable size. Never pull the plug out of the socket by the connection cable.
Note the following dimensions here (H x W x D in mm, fig. 1, page 3): – RM5310: 618 x 486 x 474 – RM5330: 821 x 486 x 474 – RM5380: 821 x 486 x 474 –...
Page 20
Installing the refrigerator RM5310 – RM5385 If the ventilation grille of the air inlet vent cannot be installed flush to the ground, an additional inlet vent (fig. 2 5, page 4) must be provided in the floor for releasing leaked gas.
Page 21
RM5310 – RM5385 Installing the refrigerator The manufacturer recommends using a flexible seal to ease removal and installation for maintenance purposes. ➤ Attach the sealing lips (fig. 3 1, page 5) to a stop rail behind the refrigerator, for example, by using an adhesive.
Page 22
Installing the refrigerator RM5310 – RM5385 Installing the ventilation grille LS100 No. in Description fig. 5, page 5 Installation frame Ventilation grille Attachment for flue duct Winter cover LS200 No. in Description fig. 6, page 5 Installation frame Ventilation grille Winter cover Proceed as follows (fig.
RM5310 – RM5385 Reversing the door ➤ Connect the flue duct and the cover plate with the T-piece (1). ➤ Shorten the flue duct (7) to the correct length if necessary. ➤ Place the LS100 ventilation grille (9) in the installation frame (6) and lock it into place.
The door panel must have the following dimensions: RM5310: 534 x 455 x max. 3 – 3.8 (H x W x D in mm) RM5330/RM5380/RM5385: 740 x 455 x max. 3 – 3.8 (H x W x D in mm) ➤...
Page 25
RM5310 – RM5385 Connecting the refrigerator It must be possible to shut off the refrigerator from the gas line separately by means of a shut-off device. The shut-off device must be easily accessible. ➤ Connect the refrigerator to the gas supply securely and without any voltage according to fig.
Page 26
Connecting the refrigerator RM5310 – RM5385 ➤ Connect the RM5310/RM5330/RM5380 refrigerators according to fig. d, page 11 (without lighting), and fig. e, page 12 (with lighting): Item Description DC heating cartridge DC connection cable Terminal strip for the DC power supply of the heating cartridge...
Page 27
RM5310 – RM5385 Connecting the refrigerator ➤ Connect the RM5385 refrigerator according to fig. f, page 13: Item Description AC heating cartridge AC power connection cable Earth AC power Ionisation Ignition Burner DC heating cartridge LED lighting Gas input Gas output...
Page 28
Connecting the refrigerator RM5310 – RM5385 ➤ Secure the power supply line to the heating element (connections 3 and 4) with a 16 A fuse and the supply for lighting/electronics (connections 5 and 6) with a 2 A fuse. ➤ Connect the heating element (connections 3 and 4) with the shortest possible cable.
RM5310 – RM5385 Cleaning and maintenance Cleaning and maintenance WARNING! Always disconnect the refrigerator from the mains before you clean and service it. NOTICE! Beware of damage Do not allow grease or oil to come into contact with the door seal.
Technical data RM5310 – RM5385 Technical data RM5310 RM5330 RM5380 RM5385 Voltage: 230 Vw 12 Vg Gross capacity: 60 l 70 l 80 l 80 l Net capacity: 55 l 65 l 75 l 75 l Connection value: 125 W (230 Vw), 120 W (12 Vg) 18.3 g/h (gas)
Page 32
Dometic DO Brasil LTDA MEXICO Regional Office Avenida Paulista 1754, conj. 111 Dometic Mx, S. de R. L. de C. V. South Africa & Sub-Saharan Africa SP 01310-920 Sao Paulo Circuito Médicos No. 6 Local 1 Unit 6-7 on Mastiff Linbro Park ...