Installation Requirements - LG LWS3081ST Installation Manual

Electric convection built-in oven
Hide thumbs Also See for LWS3081ST:
Table of Contents

Advertisement

Available languages

Available languages

Part 2

INSTALLATION REQUIREMENTS

1
The first step of the installation is measure the current cutout dimensions and compare them to the cutout
IMPORTANT NOTE
sure the base is level and the front of the cabinet is square. If the cabinet base is not level, the oven glides will
tend to slide out when opening the door.
If marks, blemishes or the cutout opening are visible above the installed oven, it may be necessary to add wood
shims under the runners and front trim until the marks or opening are covered.
to establish the cutout width.
The junction box must be flush with the rear wall of the cabinet as shown below.
Allow at least a 23" clearance for the door depth when it is open.
27 3/8"
(69.5 cm)
Recommended
29 5/16"
(74.5 cm)
29 3/4"
(75.5 cm)
Allow 1"
minimum for
overlap of oven
23"
- 4 -
23 3/8"
(59.3 cm)
30"
5"
28 1/2" Min.
28 5/8" Max.
28 15/16" Min.
29" Max.
23 1/2"
Allow 1"
Minimum cutout
minimum for
location from
overlap of oven
floor 31"
28 7/8"
(73.3 cm)
Junction Box
Location
23 1/2"

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents