Visualisation Of Parameters On The Display ("Info" Function) - DeDietrich MS 24 BIC FF Operating And Installation Instructions

High performance gas-fired wall-mounted boiler
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 59

20. VISUALISATION OF PARAMETERS ON THE DISPLAY ("INFO" FUNCTION)

i
Press "
" for at least 5 seconds to visualise certain boiler information on the display on the front panel of the boiler.
N.B:
when the "INFO" function is enabled, the message "A00", alternating with the boiler delivery temperature,
is shown on the display (figure 12):
+/-
Press buttons
(
A00: current DHW temperature (°C);
A01: current external temperature (°C) (with external sensor connected);
A02: modulation current value (100% = 310 mA);
A03: power range (%) (MAX R);
A04: heating setpoint temperature (°C) - - If the external sensor is connected, the value of the "kt" curve is displayed
(section 26);
A05: current heating delivery temperature (°C);
A06: DHW temperature setpoint (°C);
A07: — — ;
A08: value (l/minx10) of the DHW flow rate;
A09: last error that occurred in the boiler.
This function remains active for 3 minutes. It is possible to interrupt the "INFO" function in advance by pressing button
i
(
) for at least 5 seconds, or turning off the power to the boiler.
INSTALLATION INSTRUCTIONS
) to display the following information:
75
Figure 12
71.06199.02 - EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms 24 bic

Table of Contents