Osburn HYBRID-45 MF Owner's Manual

Osburn HYBRID-45 MF Owner's Manual

Osburn stoves by sb i electric heater - room heater user manual
Hide thumbs Also See for HYBRID-45 MF:

Advertisement

MODEL HYBRID-45 MF
OWNER'S MANUAL
Warning: If your appliance is not properly installed a house fire may result. For your safety, follow
the installation directions. Contact local building or fire officials about restrictions and installation
inspection requirements in your area.
PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater.
Failure to follow these instructions could result in property damage, bodily injury, or even death.
Save these instructions.
Some surfaces become hot at higher feeding rates. To prevent potential burns, avoid contact with
those areas.
PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED
Manufactured by:
Stove Builder International Inc.
Quebec City (Quebec)
CANADA
45165

Advertisement

Table of Contents
loading

Summary of Contents for Osburn HYBRID-45 MF

  • Page 1 MODEL HYBRID-45 MF OWNER’S MANUAL • Warning: If your appliance is not properly installed a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.
  • Page 2: Introduction

    INTRODUCTION Thank you for purchasing the HYBRID-45 MF pellet stove. You are now prepared to burn wood in the most efficient, convenient way possible. To achieve the safest, most efficient and most enjoyable performance from your stove, you must do three things: 1) Install it properly;...
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS • Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer. • Never use gasoline, gasoline- type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up”...
  • Page 4: Table Of Contents

    INTRODUCTION SAFETY PRECAUTIONS SPECIFICATIONS INSTALLATION Preparation Clearances Combustion Air Supply When Outside Air Is Not Used Venting ----------------------------------------------------------------------------------------------- Freestanding Installations Log set installation OPERATION --------------------------------------------------------------------------------------------------- Proper Fuel Pre-Start-Up Check Building a Fire Lighting procedure Unit Controls Opening Door Convection blower If Stove Runs Out Of Pellets Damper Control Refueling...
  • Page 5: Specifications

    NOTE: Normally, your dealer will perform these functions. CLEARANCES The Osburn Hybrid-45 MF has been tested and listed for installation in residential, mobile home.(refer figure 1 & 2) FLOOR PROTECTION: minimum 6” in the front and 6” on each side. The stove must be placed on a continuous (grouted joints) noncombustible material such as ceramic tile, cement board, brick, 3/8”...
  • Page 6: Combustion Air Supply

    VENTING The Osburn Hybrid-45 MF is certified for use with Vent type UL-103 or ULC S629M and Chimney type UL-641 or ULC S609, 3” or 4” diameter in size. This unit can be installed in an existing chimney with the addition of a liner if it’s more than 4”...
  • Page 7: Freestanding Installations

    Equivalent Vent Length (EVL) The longer the run of pipe in your installation, the more restriction there is in the system. Therefore, larger diameter pipe should be used. • Use 4” pipe if you have more than 15 feet of Equivalent Vent Length (EVL).
  • Page 8 VERTICALLY WITH NEW CHIMNEY SYSTEM (Refer to Figure 9 & 10 for basement installation) NOTE: Follow L-Vent chimney manufacturer’s instructions. OPTION: To achieve a center vertical installation, a 45º elbow and a clean-out tee can be used to offset the pipe from the exhaust outlet to the rear center of the stove.
  • Page 9 VERTICALLY INTO EXISTING FIREPLACE NOTE: Follow L-Vent chimney manufacturer’s instructions. Have the masonry chimney inspected by a qualified chimney sweep or installer to determine its structural condition. You will need a pipe length equal to the chimney height from the hearth. If outside combustion air is to be used, you will need a pipe length equal to the chimney height plus 18 inches.
  • Page 10: Log Set Installation

    OPTIONAL LOG SET INSTALLATION To install the optional log set, you first need to remove the four screws indicated on figure 14a. Keep the screws. Locate the two fixation brackets figure 14b that came with your owner’s manual. Fix the two brackets using the same screws you have removed.
  • Page 11: Operation

    (a dry cloth or paper towel is usually sufficient). Never use abrasive cleaners on the glass or door. Check fuel in the hopper, and refill if necessary. NOTE: The Osburn Hybrid-45 MF Hopper can hold up to 70 lbs. of pellets. BUILDING A FIRE Never use a grate or other means of supporting the fuel.
  • Page 12: Opening Door

    MODE SWITCH • When the mode switch is pressed, the stove will automatically ignite. If the manual mode is selected, the heat level must be selected manually to adjust the stove’s heat output to the desired level. If the thermostat mode is selected, the stove will automatically modulate between the lowest heat level and the heat level selected to keep the room temperature at the thermostat’s setting.
  • Page 13: If Stove Runs Out Of Pellets

    IF THE STOVE RUNS OUT OF PELLETS The fire goes out and the auger motor and blowers will run until the stove cools down. This will take a few minutes. After the stove’s components stop running, an error message will appear To restart, press the “RESET”...
  • Page 14: Optional Thermostat

    Location of the thermostat is very important to obtain the best comfort and efficiency from you Hybrid-45 MF. The thermostat should be mounted 50 inch from the floor on a wall located 15 to 20 feet from the stove. You should avoid an installation directly in front of the stove to avoid cycling.(See figure 17)
  • Page 15: (Please Read This) Operating Safety Precautions

    OPERATING SAFETY PRECAUTIONS a. If you notice a smoldering fire (burnpot full but no visible flame) AND a heavy smoke buildup in firebox, immediately TURN OFF the stove, but DO NOT unplug it. Do not open the door, change the damper setting or tamper with any controls on the stove.
  • Page 16: Maintenance

    ASH DISPOSAL The Osburn Hybrid-45 MF has an ash bin located below the firebox. To remove ashes: Make sure fire is out and the firebox is cool.
  • Page 17: Vacuum Use

    Your vacuum or shop vac may have a special filter or bag available to eliminate this leakage. CLEANING Heat Exchange Tubes – Your Osburn Hybrid-45 MF stove is designed with a built-in heat exchanger tube cleaner. This should be used weekly to remove accumulated ash on the tubes.
  • Page 18: Chimney Cleaning

    CHIMNEY CLEANING Creosote Formation – When any wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue or a newly started fire or from a slow- burning fire.
  • Page 19: Troubleshooting Guide

    TROUBLESHOOTING GUIDE When your stove acts out of the ordinary, the first reaction is to call for help. This guide may save time and money by enabling you to solve simple problems yourself. Problems can be caused by to only five factors: 1) poor fuel; 2) poor operation or maintenance; 3) poor installation;...
  • Page 20 TROUBLESHOOTING GUIDE STOVE SHUTS OFF AND APPEARS ON THE CONTROL BOARD Possible Causes: The hopper is out of pellets. The air damper is too far open for a low feed setting. The burn pot holes are blocked. The air inlet, the interior chambers, or exhaust system has a partial blockage.
  • Page 21 TROUBLESHOOTING GUIDE STOVE FEEDS PELLETS, BUT WILL NOT IGNITE AND Possible Causes: Air damper open too far for ignition. Blockage in igniter tube or inlet for igniter tube. Bad igniter element. The F-140 heat sensor has malfunctioned. The control board is not sending power to the igniter. STOVE FEEDS PELLETS, BUT WILL NOT IGNITE AND Possible Causes: The igniter fuse on the control board has blown.
  • Page 22 TROUBLESHOOTING GUIDE STOVE STOPS FEEDING PELLETS AND Possible Causes: The L-250 automatic high temperature switch has tripped. STOVE STOPS FEEDING PELLETS AND Possible Causes: The hopper lid has stayed open for more than 3 minutes SMOKE SMELL COMING BACK INTO THE HOME Possible Causes: There is a leak in the vent pipe system.
  • Page 23 TROUBLESHOOTING GUIDE • GLASS “SOOT’S” UP AT A VERY FAST RATE • FLAME IS LAZY, DARK, AND HAS BLACK TIPS • AFTER STOVE HAS BEEN ON FOR A WHILE, THE BURNPOT OVERFILLS Possible Causes: Stove or vent pipe is dirty, which restricts airflow through the burn pot.
  • Page 24 SMOKE SMELL OR SOOT BUILD-UP Because it is a wood-burning device, your Osburn Hybrid-45 MF may emit a faint wood-burning odor. If this increases beyond normal, or if you notice an unusual soot build-up on walls or furniture, check your exhaust system carefully for leaks. All joints should be properly sealed.
  • Page 25: Electrical Diagram

    ELECTRICAL DIAGRAM THERMOSTAT HOPPER LID TERMINALS SWITCH N.O. N.O. L2(LINE COMMON) L1(LINE HOT) L1(LINE NO CONNECTED) FRAME GROUND L-250 RESET N.C. F-140 N.O. AIR FLOW PRESSURE SWITCH N.O. L-250 N.C. F-160 N.O. HIGH TEMPERATURE SWITCH L-250 HIGH TEMPERATURE SWITCH F-160 CONVECTION BLOWER AIR SUPPLY...
  • Page 26: Replacement Parts List

    Contact an Authorized OSBURN Dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards. ITEM Airflow Pressure Switch Air Switch Hose Auger Motor Burn Pot Control Board Combustion/Exhaust Blower Assembly Convection Blower Door Gasket...
  • Page 27: Warranty

    e-mail : tech@sbi-international.com web site : www.osburn-mfg.com LIMITED LIFETIME WARRANTY The Osburn warranty extends only to the original consumer purchaser and is not transferable. This warranty covers brand new products only, which have not been altered, modified nor repaired since shipment from factory. Proof of purchase (dated bill of sale), model name and serial number must be supplied when making any warranty claim to your Osburn dealer This warranty applies to normal use only.

Table of Contents