Dispenser System Connections - Miele PW 6241 Operating Instructions Manual

Table of Contents

Advertisement

Connection to cold water supply only
1"
-See installation diagram supplied with the
machine.-

Dispenser system connections

Connections 1 and 2 are for viscous agents
only. These connections are sealed and
have to be drilled open with an 8 mm drill
bit.
M.-Nr. 06 572 495
3/4"
Notes for the installer
Be carefull to only drill through the first wall
(1). There is a second one located 10 mm
behind it to deflect the agent and this must
not be drilled into.
Any connections that have been drilled open
must be resealed if they are subsequently
not required.
Connections 3 to 12 are for liquid agents
only. These connections are also sealed and
have to be trimmed to the correct diameter
for the hoses being used with a suitable
small saw.
Any connections that have been opened
must be resealed if they are subsequently
not required.
39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Innovation m pw 6241Innovation m pw 6321Pw 6321

Table of Contents