No wire installation is required between the main and remote units. As the EMR963HG operates at 433MHz, it can be used in the U.S. and most places in Continental Europe.
Page 2
A Extra large two-line Liquid Crystal Display (LCD) Multifunction display showing temperature and humidity, max./min. memory, and trend indicators for the main unit and remote sensors. B CHANNEL button - Selects among different channels - Activates remote sensor scanning mode C IN/REMOTE - Selects between the main-unit display and a selected remote unit...
Supports the remote unit in wall-mounting Removable table stand For standing the remote unit on a flat surface BEFORE YOU BEGIN To ensure proper functioning of the EMR963HG follow this setup procedure. For best operation: 1. Assign different channels to different remote units.
Page 4
Follow these steps to install / replace batteries: 1. Remove the screws on the battery compartment. 2. Select the channel number on the CHANNEL slide switch. 3. Select the temperature display unit on the °C/°F slide switch. 4. Insert the batteries strictly according to the polarities shown therein.
GETTING STARTED Once batteries are placed in a given remote sensor unit, it will start transmitting information at 40-second intervals. Also, for approximately a 3-minute duration, the main unit will automatically search for signals once batteries are installed. Upon successful reception, the individual channel temperature reading will be displayed on the top line and the respective humidity reading on the bottom line.
The unit is in searching mode. Transmission data are securely registered. No signals. THE COMFORT-LEVEL ICONS The comfort level is based on the recorded relative humidity. An indicator will be displayed ot show if the level is comfortable, wet or dry.
Page 7
To deactivate the remote-sensor scanning mode: • Press any button. MAXIMUM AND MINIMUM TEMPERATURE AND HUMIDITY The maximum and minimum recorded temperature and humidity readings will automatically be stored in the memory. To display the maximum and minimum display memory: 1.
Note: The temperature range is from -50°C (-58°F) to +70°C (158°F). If this is the first time you set the limits, the lower limit will start from -50°C (-58°F) and the upper limit +70°C (158°F). Otherwise, the reading will start from the temperature last selected.
TRANSMISSION COLLISION Signals from other household devices, such as door bells, home security systems and entry controls, may interfere with those of this product and cause temporarily reception failure. This is normal and does not affect the general performance of the product. The transmission and reception of temperature readings will resume once the interference recedes.
THE RESET BUTTON This button is only used when the unit is operating in an unfavorable way or malfunctioning. Use a blunt stylus to hold down the button. All settings will return to their default values. PRECAUTIONS This product is engineered to give you years of satisfactory service if you handle it carefully.
General RF Transmission Frequency : 433 MHz No. of Remote unit : Maximum of 3 RF Transmission Range : Maximum 30 meters Temperature compensation : 0.1° C to ( 0.2°F) Temperature sensing cycle : around 40 seconds Power Main unit : 2 pcs UM-3 or “AA”...
If this is not posibble all direct returns must include a Return Authorization Number from Oregon Scientific, together with proof of purchase date, your name and address, shipped prepaid to Oregon Scientific Inc., 19861 SW 95th Place, Tualatin, Oregon 97062 This warranty does not cover a product subjected to abuse, misuse or accidental damage.