Yamaha WR250F Owner's Service Manual page 374

2015
Hide thumbs Also See for WR250F:
Table of Contents

Advertisement

Fault code No.
Item
2
Connection of wire harness
ECU coupler.
Check the locking condition
of the coupler.
Disconnect the coupler and
check the pins (bent or bro-
ken terminals and locking
condition of the pins).
3
Wire harness continuity.
4
Installed condition of throttle
position sensor.
Check for looseness or
pinching.
5
Applied voltage of throttle po-
sition sensor lead.
6
Defective throttle position
sensor.
15
Throttle position sensor: open or short circuit detected.
Improperly connected 
Connect the coupler securely
or repair/replace the wire har-
ness.
Open or short circuit  Re-
place the wire harness.
Between throttle position
sensor coupler and ECU cou-
pler.
black/blue–black/blue
yellow–yellow
blue–blue
Improperly installed sensor
 Reinstall or replace the
sensor.
Refer to "ADJUSTING THE
THROTTLE POSITION SEN-
SOR" on page 8-11.
Check the applied voltage.
(black/blue–blue)
Refer to "CHECKING THE
THROTTLE POSITION SEN-
SOR" on page 9-79.
Location of discon-
nected lead
Disconnected
ground lead
Disconnected out-
put lead
Disconnected
power supply lead
Check throttle position sen-
sor signal.
Execute the diagnostic mode.
(Code No. 01)
When the throttle valve is fully
closed:
A value of 11–14 is indicated.
When throttle valve is fully
open:
A value of 109–116 is indicat-
ed.
An indicated value is out of
the specified range.  Re-
place the throttle position
sensor.
9-40
FUEL INJECTION SYSTEM
Push the start switch.
Fault code number is not dis-
played  Service is finished.
Fault code number is dis-
played  Go to item 3.
Push the start switch.
Fault code number is not dis-
played  Service is finished.
Fault code number is dis-
played  Go to item 4.
Push the start switch.
Fault code number is not dis-
played  Service is finished.
Fault code number is dis-
played  Go to item 5.
Push the start switch.
Fault code number is not dis-
played  Service is finished.
Fault code number is dis-
played  Go to item 6.
Output
voltage
5V
0V
0V
Push the start switch.
Fault code number is not dis-
played  Service is finished.
Fault code number is dis-
played  Go to item 7.