Installation Requirements; Tools And Parts; Location Requirements - Maytag MGT8720DS Installation Instructions Manual

30" (76.2 cm) double oven gas ranges
Hide thumbs Also See for MGT8720DS:
Table of Contents

Advertisement

Available languages

Available languages

In the State of Massachusetts, the following installation instructions apply:
Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
I
the State of Massachusetts.
If using a ball valve, it shall be a T-handle type.
I
A flexible gas connector, when used, must not exceed 3 feet.
I
Anti-Tip
Bracket
Range Foot

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed here.
Tools Needed
Tape measure
Phillips screwdriver
TORX
T20
screwdriver
®†
®†
Flat-blade screwdriver
1
/
" flat-blade screwdriver
8
Level
Hand or electric drill
Wrench or pliers
Pipe wrench
/
" combination wrench
15
16
Parts supplied
Check that all parts are included.
LP/Natural Gas Conversion Kit (located on back of range
near lower side)
Burner grates
Burner caps
Oven racks
2 - #12 x 1
/
" screws (for mounting anti-tip bracket)
5
8
TORX and T20 are registered trademarks of Acument Intellectual Properties, LLC.
®
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation instructions.
Slide range back so rear range foot is engaged in the slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed and engaged.
Failure to follow these instructions can result in death or serious burns to children and adults.
To verify the anti-tip bracket is installed and engaged:
• Slide range forward.
• Look for the anti-tip bracket securely attached to floor or wall.
• Slide range back so rear range foot is under anti-tip bracket.
• See installation instructions for details.

INSTALLATION REQUIREMENTS

/
" (3.2 mm) drill bit
1
8
Marker or pencil
Pipe-joint compound
resistant to LP gas
Noncorrosive leak-
detection solution
For LP/Natural Gas
Conversions
/
" combination wrench
1
2
/
" (7.0 mm) nut driver
9
32
Masking tape
WARNING
Tip Over Hazard
Anti-tip bracket (taped inside upper oven with literature
package)
Anti-tip bracket must be securely mounted to the back wall or
floor. Thickness of flooring may require longer screws to anchor
bracket to subfloor. Longer screws are available from your local
hardware store.
Parts needed
Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See the "Electrical Requirements"
and "Gas Supply Requirements" sections.

Location Requirements

IMPORTANT: Observe all governing codes and ordinances. Do
not obstruct flow of combustion and ventilation air.
It is the installer's responsibility to comply with installation
clearances specified on the model/serial/rating number plate.
The model/serial/ rating number plate is located behind the
control panel.
The range should be located for convenient use in the
kitchen.
Recessed installations must provide complete enclosure of
the sides and rear of the range.
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
or microwave hood combination that projects horizontally a
minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
All openings in the wall or floor where range is to be installed
must be sealed.