Download Print this page
Oregon Scientific RMR329PA User Manual
Oregon Scientific RMR329PA User Manual

Oregon Scientific RMR329PA User Manual

Radio-controlled projection clock with indoor / outdoor temperature

Advertisement

Quick Links

1. LED status indicator
2. Wall mount hole
3. Battery compartment
4. RESET hole: Reset unit to default settings
5. CHANNEL button: Select channel 1
GETTING STARTED
POWER SUPPLY
Radio-Controlled Projection Clock
Batteries serve as a back-up power supply. For
with Indoor / Outdoor Temperature
continuous use of projector and backlight, install
Model: RMR329PA
adapter. The socket-outlet shall be installed near the
equipment and shall be easily accessible.
USER MANUAL
NOTE
will appear when power supply is not
connected.
EN
To insert batteries:
INTRODUCTION
1. Remove the battery compartment and insert
Thank you for selecting this Oregon Scientifi c
Radio-
batteries, matching polarities.
Controlled Projection Clock with Indoor / Outdoor
2. Press RESET after each battery change.
Temperature. Please keep this manual for instructions
MEANING
LOCATION
and information you should know about.
Clock / alarm area
Main unit batteries low
CLOCK OVERVIEW
Outdoor / indoor
Sensor batteries low
temperature area
FRONT VIEW
REMOTE SENSOR
1
To set up the sensor:
1. Open the battery compartment, and insert batteries,
matching polarities.
5
2. Place the sensor within 30 m (98 ft) of the main unit
using the table stand or wall mount.
2
6
3
4
1. SNOOZE: Snooze alarm; activate backlight; rotate
dual line projection display by 180°
The transmission range may vary depending on many
2. ALARM: View alarm status; set alarm
factors. You may need to experiment with various
3. CLOCK: Change display; set clock
locations to get the best results.
4.
/
: Toggle setting options; activate / deactivate
clock reception
NOTE We recommend that you use alkaline batteries
5. Projector
with this product for longer usage and consumer grade
6. TEMP: Toggle in / out temperature settings
lithium batteries in temperatures below freezing.
BACK VIEW
SENSOR DATA TRANSMISSION
Outdoor sensor:
The main unit will automatically search for the outdoor
1
3
sensor. The sensor reception icon in the remote sensor
area shows the status:
4
ICON
DESCRIPTION
5
Main unit is searching for
6
sensor(s)
2
7
A channel has been found
8
The sensor cannot be found.
NOTE If the sensor is not found, check the batteries,
obstructions, and remote unit location.
1. FOCUS: Focus the projected image
For best results:
2. Battery compartment
Place the sensor out of direct sunlight and moisture.
3. Light sensor
Position the sensor facing main unit, minimizing
4. PROJECTION: ON / OFF switch
obstructions.
5. LIGHT: Backlight ON / OFF switch
Place the sensor in a location with a clear view to
6. °C / °F: Select temperature unit
the sky, away from metallic or electronic objects.
7. RESET: Reset settings to default
Position the sensor close to the main unit during cold
8. Adapter socket
winter months.
REMOTE SENSOR
CLOCK
CLOCK RECEPTION
This product is designed to synchronize its clock
2
automatically with a clock signal.
To enable / disable signal reception:
1
Touch and hold
to enable, or
signal reception.
4
3
5
NOTE Reception takes 2-10 minutes. If the signal is
weak, it can take up to 24 hours to get a valid signal.
RMR329PA_086L004937-011.indd 1
Clock signal reception indicator:
PRECAUTIONS
STRONG
WEAK
NO
Do not subject the unit to excessive force, shock,
SIGNAL
SIGNAL
SIGNAL
dust, temperature or humidity.
Do not cover the ventilation holes with any items
such as newspapers, curtains etc.
Do not immerse the unit in water. If you spill liquid
over it, dry it immediately with a soft, lint-free cloth.
Do not clean the unit with abrasive or corrosive
MANUALLY SET CLOCK
materials.
1. Press and hold CLOCK for 2 seconds.
Do not tamper with the unit's internal components.
2. Press
or
to change the settings.
This invalidates the warranty.
3. Press CLOCK to confi rm.
Only use fresh batteries. Do not mix new and old
4. The setting order is: time zone offset, 12/24-hr
batteries.
format, hour, minute, year, day / month format,
Images shown in this manual may differ from the
month, day and language.
actual display.
When disposing of this product, ensure it is collected
NOTE Time zone offset sets the clock +/- 23 hours
separately for special treatment.
from the received clock signal time.
Placement of this product on certain types of wood
may result in damage to its fi nish for which Oregon
NOTE The language options are (E) English, (D) German,
Scientifi c will not be responsible. Consult the furniture
(F) French, (I) Italian, and (S) Spanish.
manufacture's care instructions for information.
The contents of this manual may not be reproduced
To select display mode:
without the permission of the manufacturer.
Press CLOCK to choose between clock with seconds
Do not dispose old batteries as unsorted municipal
and clock with weekday.
waste. Collection of such waste separately for special
treatment is necessary.
ALARM
Please note that some units are equipped with a
battery safety strip. Remove the strip from the battery
To set the alarm:
compartment before fi rst use.
1. Press and hold ALARM for 2 seconds to enter
alarm-setting mode.
NOTE The technical specifi cations for this product and
2. Press
/
to set hour / minute.
the contents of the user manual are subject to change
3. Press ALARM to confi rm.
indicates alarm is ON.
without notice.
To toggle alarms ON / OFF:
1. Press ALARM to display alarm time.
SPECIFICATIONS
2. Press ALARM again to turn alarm ON / OFF.
TYPE
To silence the alarms:
Press SNOOZE to silence it for 8 minutes
MAIN UNIT
OR
L x W x H
Press any other key to turn the alarm off and activate
it again after 24 hours.
Weight
TEMPERATURE
Temperature Unit
To toggle temperature unit:
Press °C / °F.
Temperature range
To toggle between outdoor / indoor sensor readings:
Resolution
Press TEMP.
/
indicates indoor and outdoor
Signal frequency
temperature.
Power
To auto-scan between sensors:
Press and hold TEMP for 2 seconds to display the
REMOTE UNIT (THN132N)
sensor's data for 5 seconds.
To deactivate auto-scan function press TEMP.
L x W x H
PROJECTOR AND BACKLIGHT
Weight
To activate Projection function:
Transmission range
Slide PROJECTION switch to ON to illuminate
Temperature range
projection continuously.
To activate Backlight function:
Power
Slide LIGHT switch to ON to illuminate backlight
continuously.
OR
ABOUT OREGON SCIENTIFIC
Press SNOOZE to turn on projector and backlight
Visit our website (www.oregonscientifi c.com) to learn
for 5 seconds.
more about Oregon Scientifi c products. If you're in
Press repeatedly to fl ip dual line projection image
the US and would like to contact our Customer Care
by 180 degrees.
department directly, please visit:
www2.oregonscientifi c.com/service/support
NOTE If projection is illuminated, do not look directly
into the projector.
OR
Call 1-800-853-8883.
For international inquiries, please visit:
www2.oregonscientifi c.com/about/international
FCC STATEMENT
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired operation.
NOTE To save battery life, the projector and backlight
will only operate continuously when adapter is installed.
WARNING Changes or modifications not expressly
The light sensor will turn off the projector automatically
approved by the party responsible for compliance could
when it detects external light sources.
void the user's authority to operate the equipment.
to disable signal
NOTE This equipment has been tested and found
RESET
to comply with the limits for a Class B digital device,
Press RESET to return to the default settings.
pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against
harmful interference in a residential installation.
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there
is no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment
and receiver.
• Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
different
different from that to which the receiver is connected.
• Consult the dealer or an experienced radio / TV
technician for help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact for
support or sales. Please call our customer service number
(listed on our website at www.oregonscientifi c.com
www.oregonscientifi c.com), or on
the warranty card for this product) for all inquiries instead.
We
Name:
Oregon Scientifi c, Inc.
Address:
19861 SW 95th Ave.,
Tualatin, Oregon
97062 USA
Telephone No.:
1-800-853-8883
Fax No.:
1-503-684-3332
declare that the product
Product No.:
RMR329PA
Product Name:
Radio-Controlled Projection Clock
with Indoor / Outdoor Temperature
Manufacturer:
IDT Technology Limited
DESCRIPTION
Address:
Block C, 9/F, Kaiser Estate,
Phase 1,41 Man Yue St.,
Hung Hom, Kowloon,
155 x 50 x 112 mm
Hong Kong
(6.1 x 1.97 x 4.41 in)
is in conformity with Part 15 of the FCC Rules.
240 g (8.5 oz)
Operation is subject to the following two conditions:
without battery
1) This device may not cause harmful interference.
°C / °F
2) This device must accept any interference received,
-5°C to 50°C
including interference that may cause undesired operation.
(23°F to 122°F)
0.1°C (0.2°F)
433 MHz
COUNTRIES RTTE APPROVAL COMPLIED
3 x UM-4 (AAA) 1.5V batteries /
All EU countries, Switzerland
CH
CH
4.5V
AC / DC adapter
and Norway
N
92 x 60 x 20 mm
(3.6 x 2.4 x 0.8 in)
62 g (2.22 ounces)
30 m (98 ft) unobstructed
-30°C to 60°C
(-22°F to 140°F)
1 x UM-3 (AA) 1.5V battery
Horloge de projection radio-pilotée
1. Indicateur DEL
2. Trou de fi xation murale
avec affi chage de la température
3. Compartiment des piles
intérieure / extérieure
4. Fente RESET (RÉINITIALISER): Réinitialise
l'appareil aux réglages par défaut
Modèle: RMR329PA
5. Bouton CHANNEL: Permet de sélectionner le canal 1
MANUEL DE L'USAGER
POUR COMMENCER
FR
ALIMENTATION ELECTRIQUE
Les piles n'ont qu'une fonction d'alimentation de
INTRODUCTION
secours. Si vous désirez utiliser continuellement le
Nous vous remercions d'avoir sélectionné cette Horloge
projecteur et le rétro éclairage, branchez l'adaptateur
secteur. La prise de courant doit être installée à
de projection radio-pilotée de Oregon Scientifi c
avec
proximité de l'équipement et facilement accessible.
affi chage de la température intérieure et extérieure.
Veuillez conserver ce guide et prendre connaissance
des instructions et informations nécessaires à
REMARQUE
s'affichera une fois le cordon
l'utilisation.
d'alimentation électrique branché.
Insérer les piles:
VUE D'ENSEMBLE DE L'HORLOGE
1. Retirez le couvercle du compartiment des piles et
insérez les piles en respectant les polarités.
VUE AVANT
2. Appuyez sur REINITIALISER (RESET) après
chaque changement de piles.
1
EMPLACEMENT
SIGNIFICATION
Zone Horloge / alarme
Piles faibles
(Appareil principal)
5
Zone de température
Piles du capteur
extérieure / intérieure
faibles
CAPTEUR A DISTANCE
2
6
Installation du capteur:
3
1. Ouvrez le compartiment des piles et insérez les piles
en respectant les polarités.
4
2. Installez le capteur à 30 m maximum (98 pieds) de
l'appareil principal à l'aide du support de table ou de
la fi xation murale.
1. SNOOZE (Rappel d'alarme): Permet d'activer le
rappel d'alarme, le rétro éclairage, permet la rotation
de l'image projetée sur deux lignes par 180°
2. ALARM: Visualisation du statut de l'alarme ; réglage
de l'alarme
3. CLOCK: Permet de modifi er l'affi chage de l'horloge
et de régler l'horloge
4.
/
: Permet d'alterner entre les options de réglage,
active / désactive la réception de l'horloge
5. Projecteur
6. TEMP: Permet d'alterner entre les réglages de la
La gamme de transmission peut varier en fonction de
température intérieure et extérieure
plusieurs facteurs. Vous pouvez expérimenter plusieurs
emplacements afi n d'obtenir les meilleurs résultats
FACE ARRIERE
possibles.
REMARQUE Nous vous recommandons d'utiliser des
piles alcalines pour un usage prolongé et des piles au
1
3
lithium pour la consommation lors de températures
inférieures au gel.
4
5
TRANSMISSION DES DONNEES DU
6
CAPTEUR
2
L'appareil principal recherchera immédiatement le
7
capteur extérieur. L'icône de réception du capteur sur
8
la zone du capteur à distance vous indique le statut de
la transmission:
ICONE
DESCRIPTION
L'appareil principal est à la
recherche du/des capteur(s)
1. FOCUS: Mise au point de l'image projetée
Une chaîne a été trouvée
2. Compartiment des piles
3. Capteur de lumière
Le capteur est introuvable
4. PROJECTION: Bouton ON / OFF
5. LIGHT: Bouton ON / OFF du rétro éclairage
6. °C / °F: Permet de sélectionner l'unité de mesure
REMARQUE Si le capteur n'est pas localisé, vérifi ez
de la température
les piles, les obstructions possibles et l'emplacement
7. RESET (REINITIALISER): Permet de réinitialiser
du capteur à distance.
les réglages par défaut
8. Prise de l'adaptateur
Pour obtenir de meilleurs résultats:
Ne placez pas le capteur directement face aux
rayons du soleil ou en contact avec des matières
DETECTEUR A DISTANCE
humides.
Installez le capteur face à l'appareil principal en
réduisant les obstructions possibles.
2
Placez le capteur directement vers le ciel, éloigné
des objets métalliques et électroniques.
Installez le capteur à proximité de l'appareil principal
1
pendant les périodes froides de l'hiver.
4
3
5
HORLOGE
RECEPTION DE L'HORLOGE
Ce produit est conçu pour synchroniser automatiquement
l'horloge avec le signal radio.
Pour activer / désactiver la réception du signal:
Maintenez le bouton
pour activer ou
pour
désactiver le signal de réception.
REMARQUE La réception prend entre 2 et 10
minutes. Si le signal est faible, 24 heures peuvent être
nécessaires pour obtenir un signal valide.
Indicateur de réception du signal de l'Horloge:
SIGNAL
SIGNAL
PAS DE
FORT
FAIBLE
SIGNAL
REGLER MANUELLEMENT L'HORLOGE
1. Maintenez le bouton CLOCK pendant 2 secondes.
2. Appuyez sur
ou
pour changer les réglages.
3. Appuyez sur CLOCK pour confi rmer.
4. L'ordre de réglage est le suivant : Fuseau horaire,
format 12/24 heures, heure, minutes, année, format
jour/mois, mois, jour et la langue.
REMARQUE La fonction de décalage horaire règle
l'horloge à +/- 23 heures de l'heure du signal reçu.
REMARQUE Les langues disponibles sont l'anglais (E),
le français (F), l'allemand (D), l'italien (I) et l'espagnol (S).
Pour sélectionner le mode d'affi chage:
Appuyez sur CLOCK pour choisir entre l'horloge avec
les secondes et l'horloge avec les jours de la semaine.
ALARME
Pour régler l'alarme:
1. Maintenez le bouton ALARM pendant 2 secondes
pour entrer dans le mode de réglage de l'alarme.
2. Appuyez sur
/
pour régler l'heure / les
minutes.
3. Appuyez sur ALARM pour confi rmer.
indique que
l'alarme est activée.
Pour activer/désactiver l'alarme:
1. Appuyez sur ALARM pour affi cher l'heure de
l'alarme.
2. Appuyez une nouvelle fois sur ALARM pour la
mettre sur ON / OFF.
Pour couper le son de l'alarme:
Appuyez sur SNOOZE, pour couper le son pendant
8 minutes
OU
Appuyez sur n'importe quel bouton pour éteindre
l'alarme et pour qu'elle se déclenche 24 heures plus
tard.
TEMPERATURE
Pour sélectionner l'unité de température:
Appuyez sur °C / °F.
Pour alterner entre les lectures du capteur intérieur
ou extérieur:
Appuyez sur TEMP.
/
indique la température
intérieure et extérieure.
Pour activer l'auto balayage entre les capteurs:
Maintenez le bouton TEMP pendant 2 secondes pour
affi cher les données du capteur pendant 5 secondes.
Pour désactiver la fonction auto balayage, appuyez
sur TEMP.
PROJECTEUR ET RETRO ECLAIRAGE
Pour activer la fonction Projection:
Positionnez le bouton PROJECTION sur ON pour
activer continuellement la projection.
Pour activer la fonction Rétro Eclairage:
Positionnez le bouton LIGHT sur ON pour activer
continuellement la rétro éclairage.
OU
Appuyez sur SNOOZE pour activer le projecteur et
le rétro éclairage pendant 5 secondes.
Appuyez plusieurs fois pour renverser l'image
projetée sur deux lignes par 180°.
REMARQUE Si la projection est activée, ne regardez
pas directement dans le projecteur.
6/5/07 9:58:16 AM

Advertisement

loading

Summary of Contents for Oregon Scientific RMR329PA

  • Page 1 1. Press and hold CLOCK for 2 seconds. with Indoor / Outdoor Temperature continuous use of projector and backlight, install 2. Press Model: RMR329PA 3. Press CLOCK to confi rm. adapter. The socket-outlet shall be installed near the 4. The setting order is: time zone offset, 12/24-hr equipment and shall be easily accessible.
  • Page 2 NO SE el Reloj Proyector Radiocontrolado con Temperatura SEÑAL Pulse RESET para volver a la configuración RECIBE Interior / Exterior (Modelo: RMR329PA) cumple con los DÉBIL predeterminada. SEÑAL requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. Tiene a su disposición una copia firmada y sellada de la...

This manual is also suitable for:

Bar339pa