NO.
Item
Operation
<Operation standby> .......... Displayed on remote controller
standby
1. When any of the DN codes listed below is displayed
Heating standby
2. Forced thermo OFF
3. All indoor units not able to engage in any of the above operations
14
4. The indoor fan has been turned off because the system is engaged in
<Heating standby> .......... Displayed on remote controller
1. Normal thermo OFF
2. During heating, the fan rotates at a breeze speed (UL or lower) or
3. Forced thermo OFF
Selection of
1. The range of operations that can be performed via an indoor unit
central control
mode
2. Setting details
TCC-Link central control
via TCCLink
15
(
Specification outline
• "P05" - Detection of an open phase in the power supply wiring
• "P10" - Detection of indoor flooding in at least one indoor unit
• "L30" - Detection of an interlock alarm in at least one indoor unit
• "COOL / DRY" operation is unavailable because at least one indoor
unit is operating in "HEAT" mode.
• "HEAT" operation is unavailable because at least one indoor unit is
operating in
"COOL / DRY" mode under priority cooling setting (bit 1 of SW11 on
outdoor I/ F P.C. board ON).
stand by in thermo OFF state.
a heat refrigerant (oil) recovery operation.
• During heating, the indoor unit goes thermo OFF as the heating
temperature setting is reached.
remains stationary to prevent cold air from being discharged
(including defrosting operation).
• "HEAT" operation is unavailable because at least one indoor unit is
operating in
"COOL / DRY" mode under priority cooling setting (bit 1 of SW11 on
outdoor I/ F P.C. board ON).
remote controller can be determined through the setting of the central
controller.
Operation on RBC-AMT32E
Operation
Operation
Start / stop
central
mode
selection
control
selection
Individual
×
Central 1
×
×
Central 2
×
Central 3
×
Central 4
×
: Accessible
: Inaccessible)
Timer
Temperature
Fan speed
setting
setting
setting
×
×
×
×
– 24 –
• "OPERATION
STANDBY
displayed
No display
provided on
wireless remote
controller
• "HEATING
STANDBY
displayed
• In the case of a
wired remote
controller,
"CENTRAL
CONTROL IN
PROGRESS
is displayed (lit up)
RBC-
while in central
AMT32E
Air flow
control mode.
display
direction
setting
• The display blinks
when a control
function
"CENTRAL
CONTROL
inaccessible to a
IN
remote controller is
PROGRESS"
chosen.
• A wireless remote
controller has the
same set of control
functions, although
there is no display.
When a control
operation is
performed via a
wireless remote
controller while in
central control
mode, a peep
sound alert (5
times) is provided.
Remarks
"
"
"

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents