Ten-Key) Gen - Icom IC-F43GT Service Manual

Hide thumbs Also See for IC-F43GT:
Table of Contents

Advertisement

INTRODUCTION
This service manual describes the latest service information
for the IC-F43GT/GS IC-F44GT/GS UHF TRANSCEIVER at
the time of publication.
MODEL
VERSION
MTG-01
USA-01
USA-02
USA-03
IC-F43GT
USA-04
(Ten-key)
GEN-01
GEN-02
AUS-02
CHN-01
MTE-01
IC-F44GT
(Ten-key)
EUR-01
MTG-01
USA-01
USA-02
USA-03
IC-F43GS
USA-04
(4-key)
GEN-01
GEN-02
AUS-02
CHN-01
MTE-01
IC-F44GS
(4-key)
EUR-01
To upgrade quality, any electrical or mechanical parts and
internal circuits are subject to change without notice or
obligation.
CAUTION
NEVER connect the transceiver to an AC outlet or to a DC
power supply that uses more than 8 V. This will ruin the
transceiver.
DO NOT expose the transceiver to rain, snow or any liquids.
DO NOT reverse the polarities of the power supply when
connecting the transceiver.
DO NOT apply an RF signal of more than 20 dBm (100 mW) to
the antenna connector. This could damage the transceiver's
front-end.
ORDERING PARTS
Be sure to include the following four points when ordering
replacement parts:
1. 10-digit Icom parts numbers
2. Component name
3. Equipment model name and unit name
4. Quantity required
<ORDER EXAMPLE>
1110003491 S.IC
TA31136FNG IC-F43GT
8820001210 Screw 2438 screw
Addresses are provided on the inside back cover for your
convenience.
Icom, Icom Inc. and
Kingdom, Germany, France, Spain, Russia and/or other countries.
FREQUENCY
CHANNEL
RANGE
SPACING
400–470 MHz
450−512 MHz
380−430 MHz
12.5/25.0 kHz
400–470 MHz
450−520 MHz
400–470 MHz
12.5/25.0 kHz
400–470 MHz
12.5/20.0/25.0 kHz
400–470 MHz
450−512 MHz
380−430 MHz
12.5/25.0 kHz
400–470 MHz
450−520 MHz
400–470 MHz
12.5/25.0 kHz
400–470 MHz
12.5/20.0/25.0 kHz
MAIN UNIT
IC-F43GT
Top cover
logo are registered trademarks of Icom Incorporated (Japan) in the United States, the United
1. Make sure the problem is internal before disassembling
the transceiver.
2. DO NOT open the transceiver until the transceiver is
disconnected from its power source.
3. DO NOT force any of the variable components. Turn
them slowly and smoothly.
4. DO NOT short any circuits or electronic parts.
insulated tuning tool MUST be used for all adjustments.
5. DO NOT keep power ON for a long time when the
transceiver is defective.
6. DO NOT transmit power into a Standard Signal
Generator or a Sweep Generator.
7. ALWAYS connect a 50 dB to 60 dB attenuator between
the transceiver and a Deviation Meter or Spectrum
Analyzer when using such test equipment.
8. READ the instructions of test equipment throughly
5 pieces
before connecting a test equipment to the transceiver.
10 pieces
REPAIR NOTES
An

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic-f44gtIc-f44gsIc-f43gs

Table of Contents