Full-Duplex - Hitachi CP-X9110 Network Manual

Hide thumbs Also See for CP-X9110:
Table of Contents

Advertisement

7. Network Bridge Function
7.4 Transmission method (continued)
NOTE
• With using the HALF-DUPLEX method, the projector can send out
254 byte data at the maximum at a time.
• If it is not required to monitor the response data from an external device and
the RESPONSE LIMIT TIME is set to OFF, the projector can receive the data
from the computer and send it out to an external device continuously.
The OFF is selected as the default setting.

7.4.2 FULL-DUPLEX

This method lets the projector make two way communication, transmitting and
receiving data at the same time, without monitoring response data from an
external device.
With using this method, the computer and an external device will send the data
out of synchronization. If it is required to synchronize them, set the computer to
make the synchronization.
NOTE
• When the computer controls the synchronization of receptions and transmissions,
the external device may not be controlled properly depending on the status of data
processing of the projector.
86