Agitator Brush Roll; Power Hand Tool Belt; Belt Replacement - Hoover U57809RM Windtunnel Cyclonic Owner's Manual

Hide thumbs Also See for U57809RM Windtunnel Cyclonic:
Table of Contents

Advertisement

Powered Hand Tool (cont.)
Replacing Agitator Brush Roll
How to Replace
4-25
B
A
belt and position belt over gear teeth (B) on
brush roll.
4-28

Belt Replacement

The powered hand tool belt is designed to last a long time and is not normally replaced. However, if
the belt is cracked, gouged or broken, it should be replaced.
Inspecting the
Belt
4-29
The belt can be seen
through the top of the
nozzle or by removing
the bottom plate and
belt guard (Figs. 4-23
to 4-24).
Remove agitator
including end plates (A)
and discard.
Inspect belt to ensure
that it is in good
condition. If belt is
cracked, gouged or
broken, replace it (see
following section).
Insert brush roll through
To replace bottom plate,
insert the four tabs on
edge of bottom plate into
slots on front of tool.
Pivot bottom plate down
and snap closed.
Replacing the
Belt
4-30
A
B
Grasp turbine (A) and
pull firmly to remove.
Remove belt from
turbine pulley (B).
Replace with new belt.
4-26
A
With curved ends
down, slide end plates
(A) of brush roll into
slots (B) on tool.
Agitator Brush Roll: What to Buy
When purchasing a new Powered Hand Tool
Agitator Brush Roll, ask for HOOVER part No.
48414-088.
4-31
Powered Hand Tool Belt: What to Buy
When purchasing a new Powered Hand Tool
Belt, ask for HOOVER part No. 38528-037.
13
4-27
A
B
Replace belt guard (A)
making sure not to
pinch brush bristles in
guard. Turn agitator,
to make sure it rotates
freely.
Replace and tighten
screws.
With flat sides of
turbine retainers (A)
pointing down, slide
retainers into grooves
(B) in tool housing and
snap into place.
Replace brush roll, belt
A
guard, and bottom plate
as described in Figs.
B
4-25 through 4-28.