Temporary or permanent temperature bypass
This operation allows you to temporarily modify the room temperature while you
are in the Automatic mode. Simply press on
temperature, or the
or
button to select the Comfort or Econo settings you
have programmed.This temperature will be maintained until the beginning of the
next programmed schedule.
You can also switch to the Vacation setting for a prolonged absence by pressing
on
and
at the same time.The display will show
the derogation is permanent. To return to the normal operating mode, press on
Mode button.
If you wish to immediately return to the programmed settings, press on Mode
button twice.
CHARACTERISTICS
• Model:
• Supply:
• Load:
• Power:
• Approvals:
• Display range:
• Setting range:
• Comfort default setting:
• Econo default setting:
• Vacation default setting:
• Storage:
PROBLEMS
No display
The thermostat is loosing
the time but not the programming
Room temperature shown is wrong
Heating system always on
The thermostat displays heating
but heating system is not turned on
Programs do not change as you want
or
button to select the desired
icon. In that case,
TH110A-SP-P (120 VAC)
120 VAC, 50/60 Hz
20 A maximum (resistive only)
2400 watts (NI) @ 120 VAC
CSA / UL
0 to 60 °C (32 to 140 °F)
5 to 30 °C (40 to 85 °F)
20 °C (68 °F)
18 °C (64 °F)
10 °C (50 °F)
-20 to 50 °C (-4 to 120 °F)
PROBLEMS AND SOLUTIONS
CAUSES
• Circuit breaker is open
• Power failure
• The thermostat switch is
in Stand by position
• Power failure more than
2 hours
• A draft is nearby the thermostat
• Bad installation
• Bad installation
• Incorrect programming hours
• Wrong programming mode selected
WARRANTY
AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY
This product is warranted against material defects and workmanship in normal
use for a period of one year, from the date of the original purchase from
authorized dealers. During this period, AUBE technologies inc. will repair or
replace the product with a new or of equivalent quality at AUBE'S option, without
charge, any product proven defective in normal use.
Warranty does not cover transportation costs. Nor does it cover a product
subjected to misuse or accidental damage. This warranty does not cover the cost
of installation, removal or reinstallation.
This limited warranty is in lieu of all other warranties, obligations or liabilities
expressed or implied by the company. In no event shall AUBE technologies inc.
be liable for consequential or incidental damages resulting from installation of this
product. Some states or provinces do not allow limitations on how long an implied
warranty lasts, or the exclusion or limitation of incidental or consequential
damages, so the above exclusions or limitations may not apply to you. This
warranty gives you specific legal rights and you may also have other rights which
vary from state to state.
The defective product and the original sale receipt must be returned to the
original dealer or shipped pre-paid, insured and addressed to:
Aube technologies inc., 705 Montrichard, Iberville (Quebec),
Canada, J2X 5K8
www.aubetech.com
service@aubetech.com
If you have any questions concerning the installation or programming of this
product, please call our technical assistance at (450) 358-4600 for the Montreal
1-800-831-AUBE
area or
for outside area, Monday to Friday between
8:30 AM and 5:00 PM Eastern time.
SOLUTIONS
• Check 120 VAC presence
at the thermostat
• Put the switch
in On position
• Eliminate the draft
• Check installation
• Check installation
• Check 120 VAC presence
at the heating system
• Check actual time
in AM & PM as well
as program times
(AM is not displayed)
• Make sure operating mode
is set to AUTO
01/04/02
920-110-001-00-1-B
3/3

Advertisement