Download Print this page

Atwood HYDRO FLAME 8935 Technical Installation Manual page 5

8900-iii-ld series
Hide thumbs Also See for HYDRO FLAME 8935:

Advertisement

A
Valve Assembly
(Vanne)
Valve Conversion
(Vanne de conversion)
6
5
8900-III DC WIRING
GROUND
ELECTRODE
YELLOW
VALVE
SAIL
YELLOW
SWITCH
RED
WHITE
LIMIT
SWITCH
BLUE
RED
YELLOW
HIGH TENSION
IMPORTANT: If any original wire has to be replaced, it must
CUSTOMER SUPPLIED WIRE
5
8900-III AC WIRING
PICTORIAL DIAGRAM
Electrode
Yellow
Green
Valve
DO NOT
Sail
+
GRIP
+
4
Switch
1
HERE
2
3
Transformer
Blue
Yellow
Red
Off
Blue
On
Limit Switch
Blue
Red
Green
HIGH TENSION
MOTOR
BLACK
RED
12V DC
SUPPLY
CIRCUIT
BREAKER
RED
ON/OFF
ON
SWITCH
OFF
RED
+ 12V DC
YELLOW
NEG
BLUE
+THERMO
BLUE
THERMO
BLW PWR
THERMOSTAT
IGNITION
BOARD
BLUE
be replaced with type 105 C or its equivalent.
Terminal Block on 85 Models only.
Motor
Black
Brown
Green
Yellow
3 3
White
2 2
Black
White
1 1
Black
AC Capacitor Motor Run
Black
Yellow
+Thermo Blue
Ignition Control
1 2 3 4 5 6
IMPORTANT If any original wire has to be replaced, it must bereplaced with the type 105 C or its equivilant.
NOTE: DC Models only
ON/OFF Switch may be sep-
arate or combined in Circuit
Breaker.
120VAC
120 VAC Green
120 VAC Black
120 VAC White
3
Thermo Blue
CAP
White
2
Black
3
HV
= High Voltage
GND = Ground
GV
= Gas Valve
EL
= Electrode
IG
= Egnition Control
MOT = Blower Motor
IND = IG Blower Motor Output
5
SCHEMATIC DIAGRAM
IG
SS
LS
t
t
PS
GND
TH
HV
R
L1
P/S
IND
V1
MOT
24 VAC
TF
PS
= IG Power Input
SS
= Sail Switch
TH
= Thermostat
LS
= Limit Switch
CAP = Capiacitor
P/S = Power Switch On/Off
TF
= Transformer
V1
= Valve Control
GND
EL
GV

Advertisement

loading

This manual is also suitable for:

Hydro flame 8940