TO PROGRAM PROGRAM PALETTE RESET
LEVELS
1. Switch to Program Palette to edit.
2. Enter Service Mode.
3. Set desired values for current Program Palette settings.
4. Write into memory by pressing MUTING then ENTER .
5. Repeat steps 1-4 for each palette.
Example
To Set RESET Level of Standard Mode to 60%
1. Switch to STANDARD Palette.
2. Enter Service Mode.
3. Change value of VPIC to 38 (38/63 = 60%)
4. Write into memory by pressing MUTING then ENTER .
5. Enter Video Menu and press RESET .
6. Reset level of picture for STANDARD PALETTE ONLY is now 38
steps.
4-7. A BOARD ADJUSTMENTS
SUB CONTRAST ADJUSTMENT (RDRV,
RDR4)
1. Input a 75% color-bar signal.
2. Set to: VIDEO mode = Standard, COLOR = Minimum,
PICTURE = 100%, GON = 0 (OFF), BON = 0 (OFF)
3. Set to Service Adjustment Mode and connect an oscilloscope to
pin 1 of CN351 on the A Board.
4. Set RDRV with 1 and 4 .
5. Adjust with 3 and 6 for: 1.85 ± 0.05 Vp-p (KV-32FV27 ONLY),
1.95 ± 0.05 Vp-p (ALL EXCEPT KV-32FV27).
6. Write into memory by pressing MUTING then ENTER .
7. Repeat steps 1-6 for RDR4 using Video 4 input.
White
1.95 ± 0.05 Vp-p (ALL EXCEPT KV-32FV27)
1.85 ± 0.05 Vp-p (KV-32FV27 ONLY)
Black
SUB BRIGHT ADJUSTMENT (SBRT)
1. Set to Service Adjustment Mode.
2. Input a gray scale pattern signal.
3. Set the PICTURE to minimum, and BRIGHT to normal.
4. Select SBRT with 1 and 4 .
5. Adjust SUB BRIGHT level with 3 and 5 so that the stripe second
from the right is faintly visible.
6. Write into the memory by pressing MUTING then ENTER .
white
second from the right
black