kD
Voltage Thresholds: Low 0 to 0.4 V dc
High 2.0 to 28 V dc
Maximum High 28 V dc
PROGRAM ENABLE INPUT (Terminal 5)
Operation: Level sensitive (maintained)
COUNT ACCURACY
Absolute when operated within specifications.
DPCl O-CC
Inputs A & B are designed for contact closures to dc common.
Speed: 0 to 20 Hz
Minimum Low Time: 10 milliseconds
Minimum High Time: 40 milliseconds
Input Impedance: 101
2KR above 5 V dc
Voltage Thresholds: Low 0 to 1.2 V dc, High 2.0 to 28 V
dc, Maximum High 28 V dc
kHz
Minimum Low Time: 80 microseconds
Minimum High Time: 20 microseconds
(These times are with a O.OV to 5.0 V swing.)
Input Impedance:
DPCl&CS
Inputs A& B require a voltage source, such as a current sourcing
sensor or a current sinking sensor used with the provided pull up
resistors.
Speed: 0 to 10
2&3)
)
Decimal Point: 5 positions, programmable
DC COMMON (Terminal 1)
EXTERNAL RESET INPUT (Terminal 4)
Resets totalizer when connected to dc common.
Minimum Low Time: 0.25 to 1 .O sec. (maintained)
The required pulse width varies with count speed, scale
factor and number of digits displayed.
Voltage Thresholds: Low 0 to 0.4 V dc
High 2.0 to 28 V dc
(TERMINALS
- 100.0000
(0.0000 scales by 100
TOTALIZER
Type: Up/Down Counting
Digits: 8 digits positive/minus sign and 7 digits negative
Scaler: 0.0001
.43' high
Front Panel Rating: NEMA-4X when mounted
with gasket provided
Case Material: Cycolac X-17
#
Operating Humidity: 90% Non-condensing
Weight: 2.2 oz. net
Display Size:
55°C
Storage Temperature: -20 to 70°C
-
0"
DPClO-BAT
PHYSICAL
Operation Temperature:
3V, lithium
Life expectancy: 5 years +
Replacement Part:
I
1.299 "
(33mm)
POWER
COUNT INPUT A (SUBTRACT); COUNT INPUT B (ADD)
Internal battery:
Recommended
Panel Cutout
I
-w
(68mm)
f--- 2.677 "
-H
7mm)
(74.93mm)
b- 2.95 "
663/0693
DPCI O-CC Add/Subtract Totalizer (Contact Inputs)
Ml
O-CS Add/Subtract Totalizer (Solid State Inputs)
DPCI

Advertisement

Table of Contents
loading

  Related Manuals for Omega Engineering DPC10-CS

  Summary of Contents for Omega Engineering DPC10-CS

  • Page 1 DPCI O-CS Add/Subtract Totalizer (Solid State Inputs) DPCI O-CC Add/Subtract Totalizer (Contact Inputs) 663/0693 b- 2.95 ” (74.93mm) POWER Internal battery: 3V, lithium Life expectancy: 5 years + Replacement Part: DPClO-BAT PHYSICAL Operation Temperature: 0” 55°C Storage Temperature: -20 to 70°C Operating Humidity: 90% Non-condensing Weight: 2.2 oz.
  • Page 2: Program Mode

    INTRODUCTION Your OMEGA DPCl 0-CS or DPCIO-CC is a counter with an eight-digit LCD display. A programmable scaler and decimal point allow for display in any engineering unit. FRONT VIEW Plastic front panel sealed to meet NEMA-4X Programming button REAR VIEW APPLICATION You must make certain programming and accomplish your application.
  • Page 3 COUNT SCALER Calculating the Count Scale Factor The count scale factor is used to convert the incoming count pulses to the desired unit of measure to be displayed (feet, gallons, etc.) or to correct for a known amount of error (wheel wear, viscosity, etc.).
  • Page 4: Wiring Diagrams

    Enabling the Front Panel Reset Key The fourth screen in the program mode allows you to enable or disable the front panel reset key. Press the m key to choose the option you want. Note: The reset terminal on the rear panel is still active when the front reset button is disabled.
  • Page 5: Replacement Parts

    REPLACEMENT PARTS DPC l O - BAT Ba tt e ry Gaske 46066-210 M oun ti ng C li p 53300-241 M oun ti ng Sc r ew 28772-200 OMEGA wa satisfactory service for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal warranty to cover handling and shipping time.
  • Page 6 OMEGA@ . . . Your Process Measurement and Control TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels Wire: Thermocouple, RTD Calibrators 8 Ice Point References Recorders, Controllers Infrared Pyrometers PRESSURE/STRAIN FORCE Transducers & Strain Gauges Load Cells 8 Pressure Gauges 5 Displacement Transducers Instrumentation 8 Accessories...

This manual is also suitable for:

Dpc10-cc