Korg PA1X User Manual page 376

Hide thumbs Also See for PA1X:
Table of Contents

Advertisement

372
Effects
Mono – Mono Chain
079: OD/HG - Amp Sim
(Overdrive/Hi.Gain – Amp Simulation)
This effect combines a mono-type overdrive/high-gain distor-
tion and an amp simulation. You can change the order of the
effect connection.
Wet: Mono In - Mono Out / Dry: Stereo In - Stereo Out
Left
Overdrive / Hi-Gain
3 Band PEQ
+
Driver
Output Level
Mode: Overdrive / Hi-Gain
Drive
Right
[O] Drive Mode
Switches between overdrive and high-gain distortion
a
Drive
Sets the degree of distortion
[O] Output Level
Sets the overdrive output level
Src
b
Selects the modulation source for the overdrive output level
Amt
Sets the modulation amount of the overdrive output level
[O] Low Cutoff [Hz]
Sets the center frequency for Low EQ (shelving type)
c
Gain [dB]
Table , "Sets the gain of Low EQ," on page 330
[O] Mid1 Cutoff [Hz]
Sets the center frequency for Mid/High EQ 1 (peaking type)
Q
d
Sets the band width of Mid/High EQ 1
Gain [dB]
Sets the gain of Mid/High EQ 1
[O] Mid2 Cutoff [Hz]
Sets the center frequency for Mid/High EQ 2 (peaking type)
Q
e
Sets the band width of Mid/High EQ 2
Gain [dB]
Sets the gain of Mid/High EQ 2
[A] Amplifier Type
f
Selects the type of guitar amplifier
Routing
g
Switches the order of the overdrive and amp simulation connection
Wet/Dry
Table , "Sets the balance between the effect and dry sounds," on page 330
Src
h
Table , "Selects the modulation source of the effect balance," on page 330
Amt
Table , "Sets the modulation amount of the effect bal-
ance," on page 330
Wet / Dry
Routing
Amp Simulation
Amp Simulation Filter
Wet / Dry
Overdrive, Hi-Gain
1...100
Fx:006
0...50
Fx:006,
Off...Tempo
–50...+50
20...1.00kHz
–18...+18dB
300...10.00kHz
0.5...10.0
Fx:006
–18...+18dB
500...20.00kHz
0.5...10.0
Fx:006
–18...+18dB
Solid State, British
(EL84), American
(6L6)
OD→AMP, AMP→OD
Dry, 1:99...99:1, Wet
Off...Tempo
–100...+100
080: OD/HG - Cho/Flng
(Overdrive/Hi.Gain – Chorus/Flanger)
This effect combines a mono-type overdrive/high-gain distor-
tion and a chorus/flanger. You can change the order of the effect
connection.
Wet: Mono In - Stereo Out / Dry: Stereo In - Stereo Out
Left
Overdrive / Hi-Gain
3 Band PEQ
+
Driver
Output Level
Mode: Overdrive / Hi-Gain
Drive
Right
[O] Drive Mode
Switches between overdrive and high-gain distortion
a
Drive
Sets the degree of distortion
[O] Output Level
Sets the overdrive output level
Src
b
Selects the modulation source for the overdrive output level
Amt
Sets the modulation amount of the overdrive output level
[O] Low Cutoff [Hz]
Sets the center frequency for Low EQ (shelving type)
c
Gain [dB]
Table , "Sets the gain of Low EQ," on page 330
[O] Mid1 Cutoff [Hz]
Sets the center frequency for Mid/High EQ 1 (peaking type)
Q
d
Sets the band width of Mid/High EQ 1
Gain [dB]
Sets the gain of Mid/High EQ 1
[O] Mid2 Cutoff [Hz]
Sets the center frequency for Mid/High EQ 2 (peaking type)
Q
e
Sets the band width of Mid/High EQ 2
Gain [dB]
Sets the gain of Mid/High EQ 2
[F] LFO Frequency [Hz]
Sets the LFO speed
f
LFO Waveform
Selects LFO Waveform
[F] Delay Time [msec]
Sets the delay time
Depth
g
Sets the depth of LFO modulation
Feedback
Sets the feedback amount
[F] Cho/Flng Wet/Dry
Sets the effect balance of the chorus/flanger
h
Output Mode
Selects the output mode for the chorus/flanger
Routing
i
Switches the order of the overdrive and chorus/flanger connection
Wet/Dry
Table , "Sets the balance between the effect and dry sounds," on page 330
Src
j
Table , "Selects the modulation source of the effect balance," on page 330
Amt
Table , "Sets the modulation amount of the effect bal-
ance," on page 330
Wet / Dry
Routing
Chorus/Flanger
Chorus/Flanger
Normal
+
Output Mode
Wet Invert
Feedback
Cho/Flng Wet / Dry
Wet / Dry
LFO: Tri / Sine
Overdrive, Hi-Gain
1...100
Fx:006
0...50
Fx:006,
Off...Tempo
–50...+50
20...1.00kHz
–18...+18dB
300...10.00kHz
0.5...10.0
Fx:006
–18...+18dB
500...20.00kHz
0.5...10.0
Fx:006
–18...+18dB
0.02...20.00Hz
Triangle, Sine
0.0...50.0msec
0...100
–100...+100
Fx:020
–Wet...–2:98, Dry, 2:98...Wet
Fx:010, 020
Normal, Wet Invert
Fx:067
OD → FLNG, FLNG → OD
Fx:067
Dry, 1:99...99:1, Wet
Off...Tempo
–100...+100

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pa1xpro

Table of Contents