Gas Conversion; Burner Features - Samsung GN641FDXD1 Installation And User Manual

Built-in hotplate
Table of Contents

Advertisement

Available languages

Available languages

Gas Conversion

■ Be careful, the operations and adjustments to be carried out when converting
from one gas to another.
■ All work must be carried out by a qualified technician.
■ Before you begin, turn off the gas and electricity supply to the appliance.
1
Change the injector of the burners.
Remove the pan support, Burner lid and Flame spreader.
Unscrew the injector using a 7mm box spanner and replace it with
the stipulated injector for new gas supply. ( see table 1. Page 27.)
Carefully reassemble the all components.
After injectors are replaced, it is advisable to strongly tighten the
injector in place.
Injector
2
Adjusting of the taps of the cooking hob burners for
reduced consumption
➀ Turn the taps down to minimum.
➁ Remove the control handles from taps.
Control handle
➂ Adjusting the by-pass screw.
Tap
Sealing ring
Tap
by-pass screw
➃ Replace the control handles on the taps.
■ Do not dismantle the tap shaft : in the event of a malfunction, change the whole tap.
■ Before placing the burners back on the top place, make sure that the injector is
not blocked.
■ A full operational test and a test for possible leakages must be carried out after
gas conversion. (such as soap water or gas detector)
■ After completing conversion, a qualified technician or installer has to mark "V"
on the right gas category
to match with the setting
in rating plate.
Remove the previous
setting "V" mark.
- For converting G20 into G30 or G31, the screw must
be screwed down fully tight.
- At this stage, light up the burners and turn the
control handles from max position to minimum
position to check flame stability.
- For converting G30 or G31 into G20, please contact
"After-Sales Service".
ELECTRONICS
GN642JDXD1
S/N: V1PT79MC300001
G20/20mbar
220-240V 50/60Hz
∑Qn Q20:8.3kW G30:591g/h G31:570g/h
GB Cat.: ll 2H3+
G20-20mbar
G30/29mbar
G31/37mbar
26

Burner Features

Nominal heat input and flow rates see below at 15˚C at 1,013 mbar.
COUN-
TYPE OF
TRY
GAS
GB,IT
FR,HU
G-30
BE,LT
BUTANE
NL,PT
29 mbar
ES,CZ
SK
G-30
PL
BUTANE
36 mbar
GB,IT
FR,BE
G-31
LT,PT
PROPANE
ES,CZ
37 mbar
SK
GB,IT
FR,BE
G-20
LT,PT
NATURAL
PL,ES
20 mbar
CZ,SK
G-20
HU
NATURAL
25 mbar
0063
- Aeration adjustment none
BURNER
Triple-Crown
Rapid
POSITION
Max
Max
Min
Min
Injector make
85
98
(1/100 mm)
Nominal heat input
0.75
3.8
2.7
3.0
(Kw)
Nominal flow rates
53
267
193
211
(L/h)
Injector make
93
80
(1/100 mm)
Nominal heat input
0.85
3.8
2.7
3.0
(Kw)
Nominal flow rates
259
185
58
203
(L/h)
Injector make
85
98
(1/100 mm)
Nominal heat input
2.5
3.8
3.0
0.7
(Kw)
Nominal flow rates
254
177
199
49
(L/h)
Injector make
135
119
(1/100 mm)
Nominal heat rating
3.8
1.4
3.0
0.78
(Kw)
Nominal flow rates
361
129
271
79
(L/h)
Injector make
128
110
(1/100 mm)
Nominal heat input
3.8
1.4
3.0
0.84
(Kw)
Nominal flow rates
350
129
271
79
(L/h)
Burner
Calibrated orifice 1/100mm
Auxiliary
Semi-rapid
Rapid
Triple-Crown
27
(Table 1)
Semi-rapid
Auxiliary
Total
Max
Max
Min
Min
65
50
-
1.75
0.43
1.0
0.37
11.3
25
120
31
71
62
47
-
1.75
0.48
1.0
0.38
11.3
125
25
33
71
65
50
-
1.75
0.4
1.0
0.33
11.3
118
28
68
23
97
72
-
1.75
0.51
1.0
0.29
11.3
54
166
91
30
91
68
-
1.75
0.57
1.0
0.32
11.3
54
166
91
30
31
34
45
65