Low cost professional infrared thermometer (20 pages)
Summary of Contents for Omega OS541
Page 1
User’ s Guide Shop online at www.omega.com e-mail: info@omega.com CAUTION LASER RADIATION DO NOT STARE INTO BEAM WAVELENGTH 800-700 mm POWER <1mW-CLASS IN LASER PRODUCT, COMPLIES WITH 21 CFR CHAPTER 1, SUBCHAPTER J. LASER RADIATION- CLASS 2 LASER PRODUCT, CONFORMS TO IEC825-1:1993...
Page 2
United Kingdom: ISO 9002 Certified It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
CONTENT I. SAFETY INFORMATION --------------------- 2 II. CAUTIONS --------------------------------------- 2 III. GENERAL SPECIFICATION ---------------- 3 IV. NAME AND FUNCTION ---------------------- 4 V. OPERATION INSTRUCTIONS: Measuring Trigger ---------------------------- 5 Distance to Spot Ratio (D/S) -------------- 5 Emissivity -------------------------------------- 5 Maintenance ------------------------------------ 6 Replace Battery -------------------------------- 6 Page...
500 MHz at 3V/m, the instrument may not meet its stated accuracy. Warning of laser! Do not point laser directly at human eye or indirectly from reflective surfaces. II. CAUTIONS Before using the infrared thermometer you notice the following: Infrared Recorder...
• When using this thermometer under large or abrupt ambient temperature changes, allow 15 minutes for unit to stabilize before use. • Do not keep this thermometer in the environment of high temperature for a long time. • Keep away from dusty environment, and keep in carry case after operation to avoid contamination of optical lenses.
IV. NAME AND FUNCTION LASER Laser dot/circle switch Laser on/off switch Measuring Trigger LCD display LCD Display Laser on indication Low battery Digital value indication CAUTION LASER RADIATION - DO NOT STARE INTO BEAM OUTPUT < 1mW AT 630 670mm CLASS II LASER PRODUCT OPEN Infrared sensor aperture...
The temperature reading will be updated on the LCD. When the operator releases the trigger, the reading will automatically be held on the LCD for 10 more seconds. After 10 seconds this thermometer will power down itself to save battery. •...
• Emissivity Emissivity is a term used to describe the energy-emitting characteristics of materials. The higher of this value means the more capability of radiation emittance the materials has. Most organic materials and painted or oxidized surfaces have an emissivity of 0.98. Metal surfaces or shiny materials has a lower emissivity and give inaccurate readings.
Page 9
Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WAR- RANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification.
Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at www.omega.com TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors...
Need help?
Do you have a question about the OS541 and is the answer not in the manual?
Questions and answers