(4) Remove the three bind B M4x12 Taptite screws and cup S M3x6 Taptite screw, and then
remove the Main shield plate ASSY.
Taptite, bind B M4x12
Taptite, bind B M4x12
Taptite, cup S M3x6
Main shield plate ASSY
Frame L
Fig. 5-127
Assembling Notes
When assembling the Main shield plate ASSY, be careful not to bend the Ground wire AL
of the Frame L.
Joint cover
Inner chute AL
Ground wire AL
Main shield plate ASSY
Fig. 5-128
5-89
Confidential