Canon iPF760 series Service Manual page 281

A4- to a0-size
Hide thumbs Also See for iPF760 series:
Table of Contents

Advertisement

(3) How to enter user name
- It is the same as the entering method of proxy server address.
(4) How to enter password
- If a password has already been set, when you press the
character.
- Entered characters are visible until you press OK key. Once entering into the menu again, they will be changed to "*".
- Other information is the same as the entering method of proxy server address.
3.2 e-RDS settings
1) Enter the service mode.
- Turn off the printer power.
- Turn on the power while pressing the [Load] key and [Navigate] key.
* Keep pressing the above keys until "Initializing" is displayed.
- "S" appears at the top right of the display.
- Press the
or
key to choose the [Set./Adj. Menu]and press the [OK] key.
* "SERVICE MODE" appears in the menu list and the MESSAGE LED flashes.
- Press the
key or
key to choose "SERVICE MODE" and press the [OK] key.
2) Set the following e-RDS setting items No.1-4.
(If the result of the communication test (COM-TEST) is "NG", execute setting items No.5-6 to solve the problem.)
No.
Item
1
E-RDS SWITCH
2
UGW-ADDRESS
3
UGW-PORT
4
COM-TEST
5
COM-LOG
6
ERDS-DAT
Proxy User
User Name Canon
: S e l e c t
S t o p
: D e l e t e
N a v i
: a -> A -> 1
[1] Entry filed (24 one-byte characters)
Proxy Password
: S e l e c t
S t o p
: D e l e t e
N a v i
: a -> A -> 1
[1] Entry filed (24 one-byte characters)
or
key at any cursor position, all the "*" will disappear and the first letter will be entered as the first
Type
2 bytes
OFF : Disable/ ON : Enable e-Maintenance/ imageWARE Remote system to send device information,
meter data, and error statuses to the UGW.
Default value is OFF (not in use)
129 bytes
The UGW address by default : https://a01---.
(NULL
The complete address is not provided in this document for security reason.
included, SJIS
not allowed)
4 bytes
The UGW Port Number by default : 443
Validation : 1-65535
To perform Communication test with UGW and set "OK!"/ "NG!" as the result.
Detailed communication data log
Switches to display time when error occurred, error code, and error data up to now.
Max 30 loggings retained.
Max 128 characters (not containing NULL) for Error information.
Initialize e-RDS setting data
[a]
[1]
[ O K : S e t ]
F-7-27
[a]
[1]
[ OK : S e t ]
F-7-28
Description
Chapter 7
7-27

Advertisement

Table of Contents

Troubleshooting

loading