MEMO:
The mist fan [1] and mist exhaust duct [2] can be removed together.
Precautions about Reinstallation of Mist Exhaust Duct
Make sure that the protrusion [1] on the mist exhaust duct fits in the notch [2] on the side plate.
c) Platen Suction Fan
Removing the Platen Suction Fan
1) Remove the output guide (right)/(middle).
2) Remove one screw [1] and disconnect one connector [2] to remove the platen suction fan [3].
[1]
[2]
F-4-96
[2]
[1]
F-4-97
[1]
[3]
F-4-98
[2]
Chapter 4
4-43