3-140 FUEL SYSTEM (DFI)
Fuel Tank
•
For the California and Southeast Asia models, note the
following.
○
To prevent the gasoline from flowing into or out of the
canister, hold the separator perpendicular to the ground.
○
Connect the hoses according to the diagram of the evap-
orative emission control system. Make sure they do not
get pinched or kinked.
○
Route hoses with a minimum of bending so that the air or
vapor will not be obstructed.
•
Pull the joint lock [A] as shown.
•
Insert the fuel outlet hose joint [A] straight onto the fuel
outlet pipe until the hose joint clicks.
•
Push the joint lock [B] until the hose joint clicks.
•
Push and pull [A] the hose joint [B] back and forth more
than two times, and make sure it is locked and does not
come off.
Make sure the hose joint is installed correctly on the
delivery pipe or the fuel could leak.
If it comes off, reinstall the hose joint.
•
Connect the fuel pump, fuel level sensor lead connectors
and the battery (–) terminal (see Battery Installation in the
Electrical System chapter).
WARNING