Note: At this time, the load source disk is the only configured disk unit in the system. The following
steps ensure that the destruction of customer data and programs will not occur.
Continue with the next step.
5. Select Start the Dedicated Service Tools.
6. Sign on to DST.
Use 22222222 as both the used ID and password. If the customer has changed the ID or password,
ask the customer for the correct values.
7. Select Work with disk units—>Work with disk unit recovery.
8. Select Recover Mirrored Load source. This function checks the disk units that are attached to the
system. If remote mirroring became enabled and a mirror-protected load-source disk unit is located, a
confirmation display appears. If a mirror-protected load-source disk unit is not located, an error display
appears.
9. After the confirmation display appears, press F10 to confirm the selection and begin the recover
function.
While the Recover remote load source function is running, SRC C6xx 4205 (xx represents the
percentage of recovery completed) displays on the system control panel.
When the Recover remote load source function completes, the system will automatically perform an
IPL from disk to the IPL or Install the System display. All of the system data, user data, and user ASPs
are now available to the system.
This ends the procedure.
Copy the contents of the LIC log:
1. From the Use Dedicated Service Tools (DST) display, select Start a Service Tool—>Licensed
Internal Code log.
2. Select either:
v Dump entries to tape from the LIC log
v Dump entries to diskette from the LIC log
3. At the bottom of the Dump entries to tape (or diskette) from LIC log display, type a 3 to dump entry
header and complete entry.
4. Then, press Enter. The system will prompt you through the remainder of the displays that are used in
this procedure. When the copy of the LIC log contents finishes, a message appears indicating that the
dump (copy) completed.
5. Press Enter. Then, select End Licensed Internal Code.
Attention: The file does not close until you select End Licensed Internal Code. If you remove the
tape or diskette before selecting this option, do not use the information that is on the tape or diskette.
This ends the procedure.

Verify the repair

For use by authorized service providers.
Choose from the following:
v If you were sent here after completing a concurrent maintenance procedure, then follow the "Verify
concurrent repair" instructions.
v If you were sent here after completing a dedicated maintenance procedure, then follow the "Verify
dedicated repair" on page 560 instructions.
Verify concurrent repair: Use this procedure to verify a repair that was performed using concurrent
maintenance.
1. Was concurrent maintenance just performed on an optical storage unit?
v No: Continue with the next step.
558