Check The Ipm Module Method - Haier AS12GB3HRA Service Manual

Table of Contents

Advertisement

Turn off the power. check if the
compressor wiring connected ok or not
Check the IPM module
Test the resistance values among
phases U, V and W of compressor, is
the resistance is about 1 ?
Check the installation condition
Disconnect the compressor harness connector from the outdoor unit PCB.
To disengage the connector, press the protrusion on the connector.
Then, measure resistance between P (+) and N (-) and the U, V and W terminals of the compressor
connector with a multi-tester. Evaluate the measurement results for a pass/fail judgment.
N(-)terminal of tester(P(+)for digital tester)
P(+)terminal of tester(N(-)for digital tester)
Normal resistance
Unacceptable resistance
YES
YES
YES
NO
Reconnect the wiring
NO
Change the IPM
Replace the
compressor
P(+)
UVW
UVW
P(+)
Short (0
or open
42
Service diagnosis
P(-)
UVW
UVW
P(-)