v Power supply 1 is the default/primary power supply. If power supply 1 fails,
v You can order an optional power supply for redundancy.
v These power supplies are designed for parallel operation. In the event of a
v For instructions on how to install a hot-swap dc power supply, refer to the
Statement 5
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current from
the device, ensure that all power cords are disconnected from the power source.
Statement 8
124
System x3650 M3 Types 4255, 7945, and 7949: Installation and User's Guide
– The server automatically shuts down if the total power consumption exceeds
the total power supply output capacity
– You can enable the power capping feature in the Setup utility to control and
monitor power consumption in the server (see "Setup utility menu choices"
on page 159)
The following table lists the system status when you install 460-watt power
supplies in the server:
Table 14. System status with 460-watt power supplies installed
Total system power
Number of 460-watt power supplies installed
consumption (in
watts)
One
< 400
Normal
400 ~ 460
Normal, status
warning
> 460
System shutdown
you must replace the power supply immediately.
power-supply failure, the redundant power supply continues to power the
system. The server supports a maximum of two power supplies.
documentation that comes with the dc power supply.
Two
Two with one failure
Normal, redundant
Normal
power
Normal, redundant
Normal, status
power
warning
Normal
System shutdown