OKILAN 310e+ Installation Guide
1
Warning: Disconnect the printer from a.c.
power before installing board.
Turn the printer around so that the rear is facing you.
2
Use a screwdriver to remove serial interface board from back panel
of printer.
If a SIMM module is present on the serial interface board, you will
need to migrate it to the SIMM 1 slot on the OKILAN 310e+ card
(see Installing SIMM Options, step 1, below).
3
Locate guide rails
and edge connector
© 1998, Okidata
.
2000 Bishops Gate Blvd. Mt. Laurel, NJ 08054 1-800-OKIDATA (800-654-3282)
Fax: 856-222-5247 http://www.okidata.com
© 1999 Okidata
4
Insert the OKILAN 310e+ into the
printer making sure that the board
locates in the guide rails. Push the
board firmly into place. Tighten the
screws (if fitted) on the option
board. If the screws do not locate,
the board may not be properly
seated.
5
After you have installed the Network Print Server:
Confirm that your printer recognizes the new components, including
any additional RAM memory, by printing the menu. Refer to your
printer's User's Guide for this procedure. Refer to your OKILAN 310e+
Network Administrator's Guide for additional information regarding
configuring and cabling details.
Installing SIMM Options
1
Use SIMM 1 slot for additional
memory only.
Use SIMM 2 for FLASH ROM option only.
2
Insert the gold metallic
contact edge of the
SIMM firmly into the
socket at a 30 degree
angle. Bring the SIMM
upright to a 90 degree
angle until the SIMM
clicks into place.

Advertisement

loading

Summary of Contents for Oki OKILAN 310Eplus

  • Page 1 OKILAN 310e+ Installation Guide Warning: Disconnect the printer from a.c. power before installing board. Turn the printer around so that the rear is facing you. Use a screwdriver to remove serial interface board from back panel of printer. If a SIMM module is present on the serial interface board, you will need to migrate it to the SIMM 1 slot on the OKILAN 310e+ card (see Installing SIMM Options, step 1, below).