2.
Connect neutral wire
Connect neutral wire (white or center) (C) of power supply cord
under center terminal block screw (B). Tighten screw.
3.
Connect remaining wires
Connect remaining wires under outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover
into slot of dryer rear panel. Secure cover with hold-down
screw. Now, go to "Connect Outlet Hose."

Direct Wire Connection

B
C
Direct wire strain relief
1.
Attach direct wire strain relief
Unscrew the removable conduit connector (A) and any
screws from a 3/4" (19 mm) UL-listed strain relief (UL marking
on strain relief). Put the threaded section of the strain relief
(C) through the hole below the terminal block opening (B).
Reaching inside the terminal block opening, screw the
removable conduit connector (A) onto the strain relief threads,
and tighten securely.
A
B
C