Recessed Area and Closet Installation Instructions
This dryer may be installed in a recessed area or closet.
This dryer must not be installed behind a lockable door,
a sliding door, or a door with a hinge on the opposite side
to that on the dryer.
The installation spacing is in millimeters and is the minimum
allowable. Additional spacing should be considered for ease
of installation, servicing, and compliance with local codes and
ordinances.
If installed in a closet with a door, the minimum unobstructed air
opening in the top and bottom is required. Louvered doors with
equivalent air openings are acceptable.
The dryer must be exhausted outdoors.
No other fuel-burning appliance may be installed in the same
closet as the dryer.
Minimum Installation Clearances
381 mm
(15")*
0 mm (0")
Recessed front view
Additional clearances for wall, door, and floor moldings may be required
or if external exhaust elbow is used.
310 cm
2
48 in.
2
(310 cm
2
)
(48 in
2
.)*
Front
closet
Front
Closet
View
View
door
door
155 cm
2
24 in.
2
(155 cm
2
)
(24 in
2
.)*
356 mm
(14") max.
Closet
door
0 mm
(0")
0 mm (0")
25 mm (1")
Closet side view
76 mm
3"
(76 mm)
(3")
*Opening is the minimum
for a closet door.
Louvered doors with
equivalent air openings
are acceptable.
76 mm
3"
(3")
(76 mm)
Product Dimensions 686 mm (27") dryer
686 mm (27")
ELECTRIC
BACK VIEW
330 mm
152 mm
(13")
(6
3
")
4
GAS
32 mm
(1
1
")
4
743 mm (29
673 mm (26
SIDE VIEW
889 mm
(35")
25 mm
(1")
Electrical Requirements – Gas Dryer
IMPORTANT: Observe all governing codes and ordinances.
You will need an earthed electrical outlet located within 610 mm
(2 feet) of either side of the dryer.
This dryer is supplied/fitted with an electricity supply cord and
plug. It should be connected to electricity supply socket at the
voltage shown on the rating plate. The minimum supply fuse
capacity should be 5A. The dryer must be positioned so that the
plug is clearly visible and accessible. This plug also provides the
function of an emergency stop control for the user. If the fitted
plug is not used, the electrical connection must be carried out
by a competent electrician in accordance with local or national
codes.