  • Page 1 INTENDED FOR DOMESTIC COOKING ONLY READ AND SAVE THESE INSTRUCTIONS INSTALLER: LEAVE THIS MANUAL TO HOMEOWNER. HOMEOWNER: USE AND CARE INFORMATION ON PAGES 11 TO 13 NuTone Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687) www.nutone.com V07451 rev A...
  • Page 2: To Reduce The Risk Of Fire, Electric Shock Or Injury To Persons, Observe The Following

    To reduce the risk of fire and electric shock, the NuTone premier NP64000 Series hood must be installed with NuTone interior blower models P5 or P8; NuTone exterior blower models 331H, 332H, 335 or 336; NuTone in-line blowers models HLB3, HLB6, HLB9, HLB11.
  • Page 3: Range Hood System

    Duct ” x 14”) Adapter and damper 3 ’’ x 14’’ (supplied with P8 blower) NP64000 SERIES HOOD Model P8 dual-blower (900 cfm) for use with 36’’ hoods or wider NOTE: The dual blower P8 must be installed with 3 ’’...
  • Page 4 (10” Rd wall cap) Model 335 (1200 cfm) or 336 (1500 cfm) Model 331H (600 cfm) or 332H (900 cfm) exterior blower Model 421 (10” Rd. vert. in-line damper) Recommended for use with exterior blowers NP64000 SERIES HOOD exterior blower...
  • Page 5: Select Blower Option And Install Ductwork

    1. SELECT BLOWER OPTION AND INSTALL DUCTWORK Either an interior or exterior blower or in-line blower may be used with this hood. The NuTone premier NP64000 Series must be installed with blower models P5, P8, HLB3, HLB6, HLB9, HLB11, 331H, 332H, 335 or 336 only. Other blowers cannot be substituted.
  • Page 6: Prepare The Installation

    2. PREPARE THE INSTALLATION Make sure that the following items are included: - Range hood - Accessories: • Filters • Bag of parts including: (4) lock nuts, (1) wire clamp, (8) ” standard screws, (6) Parts sold separately: - Interior blower Model P5 includes blower, rough-in kit, flow deviator and 3 - Interior blower Model P8 includes blower, rough-in kit, flow deviator and 3 - In-line blower assembly HLB3, HLB6, HLB9 or HLB11 (all include transition) - In-line and exterior blower rough-in plate model 332KR, required for all In-line or Exterior Blowers...
  • Page 7 5. CHOOSE THE OPENING (INTERIOR BLOWER) Remove the knockout for the chosen opening (horizontal at the back of the hood or vertical on rough-in plate). See pictures below. When using P5 blower, remove the 10’’ wide knockout (smaller part). If using P8 blower, remove the knockout corresponding to the ducting installed (10’’...
  • Page 8 8. INSTALL THE ADAPTER (INTERIOR BLOWER) Using two (2) standard ’’ screws, secure the adapter to the top (or back) of the hood. Seal the adapter to the hood using duct tape. HD0005 9. INSTALL THE HOOD (ALL BLOWERS) INTERIOR BLOWER: Run power cable to installation location. Place the hood to its location. Mark the position of the screws (smaller part of the key holes) with a pen.
  • Page 9: Connect Wiring (All Blowers)

    10. CONNECT WIRING (ALL BLOWERS) Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power to be switched on accidentally. INTERIOR BLOWER: Connect cable into wiring box using wire connectors.
  • Page 10 11. INSTALL THE BLOWER (INTERIOR BLOWER) Install screws into the location as shown in the pictures below (single blower or dual blower). Do not tighten screws down fully, leave a ” gap. Hang blower unit onto blower plate (screws through the large part of the keyhole). Slide the blower to its position (screws in the small part of the keyhole).
  • Page 11: Light Bulbs

    12. LIGHT BULBS This range hood uses 50W halogen lamps. (120V, 50W, PAR 20) Install the lamps by rotating them clockwise into their socket holder. 13. HEAT LAMPS The heat lamps required are 120V, 175W max, infrared bulbs. (120V, IR 175W, PAR 38) White halogen lights can be used if warming shelves are not used.
  • Page 12: Operation

    15. USE AND CARE (CONT’D) Hood cleaning Stainless steel cleaning: How to maintain its « BRIGHT LOOK » - Regularly wash surfaces with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent. - Always clean in the direction of original polish lines. - Always rinse well with clear water (2 or 3 times) after cleaning.
  • Page 13: Warranty

    This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify NuTone at the addres or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
  • Page 14: Service Parts

    SERVICE PARTS NP64000 Series HL0073 PART NUMBER SOCKET LAMP V02264 MALE CONNECTOR V02773 V02772 FEMALE CONNECTOR V03435 THERMOSTAT V03436 THERMOSTAT BRACKET V03501 SPEED CONTROLLER V03507 SPST SINGLE SWITCH FOR WARMING LAMP SPST DOUBLE SWITCH FOR HALOGEN LIGHT V03502 SPST LIGHTED SINGLE SWITCH FOR BLOWER...
  • Page 15 SERVICE PARTS SINGLE BLOWER/ROUGH-IN (Model P5) HL0021 PART NUMBER V13296 ADAPTER AND DAMPER 3 V03500 AIR DEFLECTOR V12997 SINGLE BLOWER ROUGH-IN PLATE ASSEMBLY V03577 FOAM ” x V02160 CAPACITOR 15MFD V01869 MACHINE SCREW #6-32 x V01857 WIRE COVER V01582 LOCK NUT #6-32 V14973 SINGLE BLOWER ASSEMBLY V01810...
  • Page 16 SERVICE PARTS DUAL BLOWER/ROUGH-IN (Model P8) PART NUMBER V14971 ADAPTER AND DAMPER 3 V13296 ADAPTER AND DAMPER 3 V03500 AIR DEFLECTOR V14975 DUAL BLOWER ROUGH-IN PLATE ASSEMBLY V03577 FOAM ” x V01582 LOCK NUT #6-32 V02160 CAPACITOR 15MFD V01857 WIRE COVER V01766 MOTOR 165W CW V03400...