14-6 ELECTRICAL SYSTEM

Precautions

There are a number of important precautions that need to follow
during servicing electrical systems. Learn and observe all the rules
below.
The electrical parts should never be struck sharply, as with a hammer,
or allowed to fall on a hard surface. Such a shock to the parts can
damage them.
Troubles may involve one or in some cases all items. Never replace
a defective part without determining what CAUSED the failure. If the
failure was caused by some other item or items, they too must be
repaired or replaced, or the new replacement will soon fail again.
Make sure all connectors in the circuit are clean and tight, and
examine wires for signs of burning, fraying, etc. Poor wires and bad
connections will affect electrical system operation.
Measure coil and winding resistance when the part is cold (at room
temperature).
Color Codes:
BK: Black
BL: Blue
BR: Brown
CH: Chocolate
DG: Dark green
G: Green
Electrical Connectors
Female Connectors [A]
Male Connectors [B]
GY: Gray
R: Red
LB: Light blue
SB: Sky Blue
LG: Light green
W: White
O: Orange
Y: Yellow
P: Pink
PU: Purple