Installing and Connecting the Outdoor Unit Drain Hose

SH
YAA(B)
Drain hole
The Others
Hole 3
Hole 2
Hole 1

Fixing the Unit in Position

"X" mm
Rubber leg
Model
X
SH
YAA(B)
252
The Others
256
14
E-
When using the air conditioner in the heating mode, ice may accu-
mulate. During de-icing, the condensed water must be drained off
safely. Consequently, you must install a drain hose on the outdoor
unit, following the instructions below.
1
Insert the drain plug into the hole 1 on the underside of the outdoor unit.
Close hole 3 with Cap Drain A.
Close hole 2 with Cap Drain B.
2
Connect the drain hose to the drain plug.
3
Ensure that the drained water runs off correctly and safely.
The outdoor unit must be installed on a rigid and stable base to
avoid any increase in the noise level and vibration, particularly if the
outdoor unit is to be installed close to a neighbour.
If it is to be installed in a location exposed to strong winds or at a
height, the unit must be fixed to an appropriate support (wall or
ground).
1
Position the outdoor unit so that the air flow is directed towards the out-
side, as indicated by the arrows on the top of the unit.
2
Attach the outdoor unit to the appropriate support using anchor bolts.
3
If the outdoor unit is exposed to strong winds, install shield plates around
Y
the outdoor unit, so that the fan can operate correctly.
506
600
Certainly fix up its rubber leg, in order to prevent its vibration and noise.