2.10 Connection of Doorphones, Door Openers,
External Sensors, and External Relays
2.10.1 Connection of Doorphones, Door Openers, External
Sensors, and External Relays
The Hybrid IP-PBX supports a maximum of 16 doorphones (KX-T30865 with a DPH4 card, or German-type
doorphone with a DPH2 card), 16 door openers, 16 external sensors, and 16 external relays.
Notes
KX-T30865 is a Panasonic doorphone.
German-type doorphones, door openers, external sensors, and external relays are user-supplied.
Maximum Cabling Distance
Installing the Doorphone (KX-T30865)
1.
Loosen the screw to separate the doorphone into 2 halves.
Screw

2.10 Connection of Doorphones, Door Openers, External Sensors, and External Relays

Cable
ø 0.4 mm:
ø 0.5 mm:
ø 0.6 mm:
CAT 5:
Maximum Distance
70 m
113 m
180 m
113 m
Doorphone
Door Opener
External Sensor/
External Relay Device