7800 PTOG: 7800 Watt Power Take-Off Generator Read this manual. Serious injury or death can result if safety instructions are not followed. Any Questions, Comments, Problems or Parts Orders Call NorthStar Product Support 1-800-270-0810 M165951C Item Number: Serial Number: WARNING DANGER...
TRAINING AND INSTALLATION WARNING: 1. Read the Operator’s Manual completely before attempting to use the generator. Serious injury or death can result if safety instructions are not followed. 2. Do not allow anyone to operate the generator who has not read the Operator’s Manual or has not been instructed on the safe use of the generator.
Warning Label Locations DANGER! ROTATING DRIVELINE−CONTACT CAN CAUSE DEATH. NEVER OPERATE WITHOUT: WARNING! NEVER operate generator in an NEVER operate generator with enclosed area. (Exhaust gases loose, broken or missing parts. NEVER operate generator under contain carbon monoxide, an odorless and deadly poison.) wet conditions, electric shock NEVER refuel a hot or running may occur.
Unpacking Closely inspect all contents in the shipping carton. - If you have damaged components: Contact the freight company that delivered the unit and file a claim. - If you have missing components: Contact Product Support at 1-800-270-0810. Assembly The gearbox is shipped with oil. Remove the shipping plug and install the filler/breather plug. Make sure that the gear oil level is in the middle of the sight glass;...
Machine Component Identification 1. Alternator. Also called generator head. 2. Grounding Screw. Use to ground the generator to a copper pipe or rod that is driven into moist soil. 3. Isomounts. Reduces vibrations transmitted to the control box 4. 30A Circuit Breaker. Thermal magnetic breaker protects against overcurrents and short circuits.
Choose a location where the generator will not be exposed to rain, snow or direct sunlight. Common places for mounting your PTO generator are to a trailer or a cement slab. Make sure it is as close to the load as possible.
1. Engaging the PTO While seated on the tractor and the engine at idle, engage the PTO. Slowly increase the throttle until the needle in the generator voltmeter is at or above the black line in the green area. 2. Applying a Load It is important to determine the total electrical load before it is connected to the generator.
Page 10
4. Starting Electric Motors Electric motors require much more current (amps) to start than to run. Some motors, particularly low cost split-phase motors, are very hard to start and require 5 to 7 times more current to start than to run. Capacitor motors are easier to start and usually require 2 to 4 times as much current to start than to run.
Problem Voltage too low Circuit breaker trips Voltage too high Generator overheating No output voltage Excessive gearbox noise Cause A- Tractor throttle set too low B- Generator is overloaded C- Defective load connected to generator D- Defective receptacle E- Defective circuit breaker F- Tractor throttle set too high G- Insufficient ventilation H- Broken or loose wire...
Specifications and Accessories Item Number Maximum Output Continuous Output Voltage Phase Frequency Power Factor Minimum PTO HP Input Shaft 120V Receptacle 120/240V Receptacle Circuit Breaker Gear Box Gear Ratio Gear Oil Oil Capacity Dimensions Length Width Height Gross Weight PTO Driveline PTO Trailer The manufacturer reserves the right to make improvements in design and/or changes in specifications at any time without incurring any obligation to install them...