INDOOR UNIT Error Method:
Number of Indoor Units Error
Detective Actuators:
Indoor Unit
Forecast of Cause :
1. Indoor unit connection failure
Check Point 1 : Check the indoor unit number connection
Check the indoor unit number connection.
>> If there is an abnormal condition, correct it by referring to Installation Manual
or Design & Technical Manual.
>> Upon correcting incorrect setting, reset the power.
Indicate or Display:
Outdoor Unit : E. 24. 2
Indoor Unit
: Operation LED 2 times Flash, Timer LED 4 Times Flash,
Economy LED Continuous Flash.
Error Code
: 24
Detective details:
When the total connection number of indoor units is outside of range
between 2 and 8.
02-22