5.4

Work order

5.5

Inserting DTE interface units

DN01145897
Issue 2-0 en
First examine the unit and make sure that it has not been damaged during
transportation. Also, check that you have the cables needed for connections
(mains cable, DTE cable, line cable).
Then proceed according to the steps below:
1.
Insert DTE interface units into the DNT2Mi terminal, if needed, refer to
Section 5.5.
2.
Insert DNT2Mi in a special shelf-like modem subrack or on a wall, if
needed, refer to Section 5.7. Otherwise, proceed with the free-standing
installation described in Section 5.6.
3.
Plug the mains cord into a grounded mains outlet (AC version) or connect
the DC power lines (refer to Section 5.8).
4.
Connect DNT2Mi to your DTE and to the line.
5.
Switch on the power (AC or DC). The modem performs a self test.
6.
Adjust the LCD contrast, if needed, refer to Section 5.9.2.
Then proceed to check that the main settings are correct (the settings are
described in Chapter 6). The settings can be checked and altered using
either the front panel keys and display (Chapter 8) or by using the Q1
connection (Chapter 9).
Caution
The equipment is sensitive to static electricity. When handling the units you
should follow the general instructions concerning handling of ESD-sensitive
equipment. You should always take antistatic precautions (such as a wrist
grounding) when handling a plug-in unit once it has been removed from its
antistatic packaging.
If the DTE interface units are not pre-inserted or a unit needs to be changed,
follow the instructions below.
© Nokia Corporation
Nokia Proprietary and Confidential
Installing DNT2Mi
25 (128)