Parameter
Number of RF channels
Channel spacing
Number of Tx power levels

Battery endurance

Battery
BP-4L
Charging times

Environmental conditions

Environmental
condition
Normal operation
Reduced performance
Intermittent or no
operation
No operation or
storage
Page 1 –16
GSM850: 124
GSM900: 174
GSM1800: 374
GSM1900: 299
WCDMA V (850): 108
WCDMA II (1900): 289
WCDMA I (2100): 277
200 kHz (WCDMA V and II 100/200 kHz)
GSM850: 15
GSM900: 15
GSM1800: 16
GSM1900: 16
WCDMA V (850): 75
WCDMA II (1900): 75
WCDMA I (2100): 75
Capacity (mAh)
1500
Ambient temperature
o
o
-10
C ... +55
C
o
o
55
C ... +70
C
o
o
-40
C ... -15
C and +70
o
o
<-40
C and >+85
C
COMPANY CONFIDENTIAL
Copyright © 2009 Nokia. All rights reserved.
Talk time
GSM: up to 400min
WCDMA: up to 320min
AC-10
4h
Specifications fulfilled
Operational only for short periods
o
o
Operation not guaranteed but an
C ... +85
C
attempt to operate will not damage
the phone
No storage. An attempt to operate
may cause permanent damage
RM-505; RM-506
General Information
Unit
Stand-by
GSM: up to 430h
WCDMA: up to 400h
Notes
Issue 1