Fig. 21 and 22, EBI RS-485 multi-drop wiring diagrams require the 8003-321 Assembly. Fig. 21 shows a Network Interface Card
(NIC) in the PC and Terminal Server with an RS-485 Interface. Fig. 22 shows a Black Box RS-232 to RS-485 Converter on the
PC side.
INTELLIGUARD CONTROL PANEL 1
INTELLIGENT COMMUNICATIONS
PROCESSOR II (ICP II) 8003-331
COM 3
12V
DTR
DIR
Rx
Tx
IN
OUT
DS3
RS-232
1 2 3 4 5 6 TB2
TB1
3 2 1
U1
U2
PSEUDO
TB2
1
RS-232 TO
UNIT 1
RS-485
1 2 3 4
INTERFACE
(RRI)
8003-322
ADDITIONAL BAUD RATES
REMOTE PROG.
NONE
4800
NOTE: EBI SOFTWARE SUITE IS PRESENTLY LIMITED TO 1200 AND 2400 BAUD.
BIAS
E.O.L.R.
TERMINATION
SET THE SWITCHES ON UNIT 1 (FARTHEST FROM THE PC) FOR BIAS DISABLED (S1-1/S1-4 OFF) AND EOLR TERMINATION ENABLED (S1-2/S1-3 ON). ON UNIT 4
1
ENABLE THE RS-485 TERMINATOR AND LINE BIAS. (THIS IS BASED ON THE ASSUMPTION THAT UNITS 1 AND 4 ARE EXTREME OPPOSITE DEVICES WITH THE
LONGEST CABLE LENGTH BETWEEN THEM, NOT NECESSARILY THE DEVICES THAT ARE PHYSICALLY LOCATED THE FARTHEST APART.)
2
SET THE SWITCHES OF UNIT 2 (AND ANY OTHER IMMEDIATE UNITS) TO OFF.
3
NOTICE THAT THE DAT – AND DAT + CONNECTION MUST BE INVERTED AT UNIT 4. THIS IS REQUIRED SINCE THE RRIs FOLLOW THE I9000
STANDARD WHICH IS THE REVERSE OF THE INDUSTRY STANDARD.
NOTES:
A MAXIMUM OF FOUR RS-485 DEVICES MAY BE CONNECTED IN A MULTI-DROP CONFIGURATION, INCLUDING THE TERMINAL SERVER.
THE GROUND BETWEEN UNITS 1 (TB2-1), 2 (TB2-1), 3 (TB2-1) AND 4 (GND) ARE NOT NECESSARY IF A GROUND REFERENCE IS PROVIDED THROUGH OTHER MEANS. ONLY
ONE GROUND REFERENCE MUST BE USED TO PREVENT GROUND LOOPS.
IN THE CONFIGURATION SHOWN, THE I9000 CONTROL PANELS ONLY COMMUNICATE WITH THE EBI PC; THEY DO NOT COMMUNICATE OR SHARE INFORMATION
PEER-TO-PEER.
Fig. 21. EBI RS-485 multi-drop wiring (using a NIC in the PC and Terminal Server with RS-485 Interface).
INTELLIGUARD CONTROL PANEL 2
INTELLIGENT COMMUNICATIONS
PROCESSOR II (ICP II) 8003-331
+
DS3
RS-232
TB1
S1
4
3
2
1
ON
2
UNIT 2
SUPPORTED BAUD RATES - 75, 150, 300, 600, 1200 & 2400
FIRMWARE
PART NO.
SMP/EBI ORBIX
NONE
8950-100
4800
8950-109
BIAS AND TERMINATION
S1
= DON'T CARE
4
3
2
DISABLE
ENABLE
DISABLE
ENABLE
COM 3
12V
DTR
DIR
Rx
Tx
+
IN
OUT
1 2 3 4 5 6 TB2
3 2 1
U1
U2
S1
4
3
2
1
ON
PSEUDO
TB2
RS-232 TO
RS-485
1 2 3 4
INTERFACE
(RRI)
8003-322
SOFTWARE VERSION
I9000 XSM (SMP PROTOCOL)
I9000 EBI ORBIX
AC POWER IN
UPS 1
AC POWER OUT
1
POSITION
OFF
ON
OFF
ON
AC POWER IN
OFF
UPS 2
ON
AC POWER OUT
OFF
ON
21
INTELLIGUARD 9000™
INTELLIGUARD CONTROL PANEL 3
INTELLIGENT COMMUNICATIONS
PROCESSOR II (ICP II) 8003-331
COM 3
12V
DTR
DIR
Rx
Tx
+
IN
OUT
DS3
RS-232
1 2 3 4 5 6 TB2
TB1
3 2 1
U1
U2
S1
4
3
2
1
ON
PSEUDO
TB2
2
RS-232 TO
UNIT 3
RS-485
1 2 3 4
INTERFACE
(RRI)
8003-322
4
LEVER
3
TERMINAL SERVER
WITH RS-485 PORT
1
UNIT 4
NETWORK (LAN/WAN) TCP/IP
EBI PC
WITH NETWORK
INTERFACE CARD
S1
3
2
1
ON
M14487
74-3047—1