Fault
Unit cannot be started.
Inadequate water flow rate.
Inadequate suction power.
Unsatisfactory cleaning
result.
Brushes do not rotate.
32
! Drain off and dispose of dirty water and
any residual cleaning liquid.
If faults cannot be rectified with the aid of
this table, contact customer service.
Remedial action
Press in the overload fuse.
Check batteries; if required, replace.
Check fresh-water level; if required, top up tank.
Check hoses for blockages; remove any blockages.
Clean container cover seals and check for leaks;
if required, replace.
Clean fluff strainer.
Clean squeegee blades on the suction bar; if required,
replace.
Check suction hose for blockages; remove any
blockages.
Check suction hose for leaks; if required, replace.
Check whether metering valve on the dirty-water drainage
hose is closed.
Check the setting of the suction bar.
Check the brushes for wear and suitability and, if required,
replace.
Check whether the brushes are blocked by foreign
objects; if required, remove foreign objects.