(4) Auto restart
Enable or disable automatic system restart after a power outage.
(♦... Factory setting)
Function
Setting description
Setting value
number
Yes
00
40
No
01
* Auto restart is an emergency function such as for power failure etc. Do not start and stop
the indoor unit by this function in normal operation. Be sure to operate by the control unit,
or external input device.
(5) Indoor room temperature sensor switching function
(Only for Wired remote controller)
The following settings are needed when using the Wired remote controller temperature
sensor.
(♦... Factory setting)
Function
Setting description
Setting value
number
No
00
42
Yes
01
* If setting value is “00” :
Room temperature is controlled by the indoor unit temperature sensor.
* If setting value is “01” :
Room temperature is controlled by either indoor unit temperature sensor or remote con-
troller unit sensor.
(6) External input control
“Operation/Stop” mode or “Forced stop” mode can be selected.
(♦... Factory setting)
Function
Setting description
Setting value
number
Operation/Stop mode
00
(Setting forbidden)
46
01
Forced stop mode
02
(7) Room temperature control switching
• This setting is used to set the room temperature control method when the wired remote
controller is selected by the Indoor Room Temperature Sensor Switching Function.
(♦... Factory setting)
Function
Setting description
Setting value
number
Control by the sensors of both the
00
indoor unit and the wired remote
controller.
48
Control only by the sensor of the
01
wired remote controller
Setting record
• Record any changes to the settings in the following table.
Setting
Setting Value
(1) Filter sign
(2) Cooling room temperature correction
(3) Heating room temperature correction
(4) Auto restart
(5) Indoor room temperature sensor switching
function
(6) External input control
(7) Room temperature control switching
After completing the FUNCTION SETTING, be sure to turn off the power and turn it on
again.
9379123037-02.indb 11
9379123037-02.indb 11
SETTING THE ROOM TEMPERATURE DETECTION
LOCATION
The detection location of the room temperature can be selected from the following 2 examples.
Choose the detection location that is best for the installation location.
A. Indoor unit setting (factory setting)
The room temperature is detected by the indoor unit temperature sensor.
(1) When the THERMO SENSOR button is pressed, the lock display fl ashes because the
function is locked at the factory.
A
Indoor unit
B. Indoor unit/remote controller setting (room tempera-
ture sensor selection)
The temperature sensor of the indoor unit or the remote controller can be used to detect
the room temperature.
(1) Enable the room temperature sensor selection in FUNCTION SETTING, which will be
“(5) Indoor room temperature sensor switching function”.
(2) Press the THERMO SENSOR button for 5 seconds or more to select the temperature
sensor of the indoor unit or the remote controller.
B
Indoor unit
CAUTION
When select the “Remote controller setting”, if the detected
temperature value between the temperature sensor of the in-
door unit and the temperature sensor of the remote controller
varies signifi cantly, it is likely to return to the control status of
temperature sensor of the indoor unit temporarily.
As the temperature sensor of remote controller detects the temperature near the
wall, when there is a certain difference between the room temperature and the
wall temperature, the sensor will not detect the room temperature correctly some-
times.
Especially when the outer side of the wall on which the sensor is positioned is
exposed to the open air, it is recommended to use the temperature sensor of the
indoor unit to detect the room temperature when the indoor and outdoor tempera-
ture difference is signifi cant.
The temperature sensor of the remote controller is not only used when there is a
problem in the detection of the temperature sensor of the indoor unit.
NOTES
If the function to change the temperature sensor is used as shown in examples A (other
than example B), be sure to lock the detection location. If the function is locked, the lock
display
will fl ash when the THERMO SENSOR button is pressed.