Detection
Conditions
Supposed Causes
Thermistor resistance check
Thermistor resistance check method:
thermistor.
HSU-18HEA03/R2(DB)-I
E1: Room temperature sensor failure
E2: Heat-exchange sensor failure
Is it normal?
YES
Is it normal?
NO
Correct the connection
NO
Replace the thermistor
YES
Replace the indoor unit PCB